Technical Specifications

61
Holdowns
© 2015 MiTek. All rights reserved.
TA Foundation Straps
HPA / PA / PAI Purlin Anchors
HPA series – For installation into poured concrete walls,
foundations, or masonry. The HPA is the heavy-duty version
of the PA anchor.
PA series – For installation into poured concrete or concrete
block walls and foundations.
PAI series – For wood I-Joist applications. An expanded 3"
on-center nail spacing reduces splitting along I-Joist ange.
Materials: HPA – 10 gauge; PA & PAI – 12 gauge
Finish: G90 galvanizing
Options: See chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Key Chart
IBC 1620.2.1
Uplift
2
Uplift
2
Uplift
2
Uplift
2
W L L1 Qty Type 160% Qty Type 160% Qty Type 160% Qty Type 160%
2 1/2 1340 3 1/2 1950 4 1/2 2475 5 1/2 3230
8 16d x 2-1/2 1905 10 16d x 2-1/2 2385 14 16d x 2-1/2 3230 16 16d x 2-1/2 3230
2 1/2 1340 3 1/2 1950 4 1/2 2475 5 1/2 3230
8 16d x 2-1/2 1905 10 16d x 2-1/2 2385 14 16d x 2-1/2 3230 16 16d x 2-1/2 3230
1) Bolt values are for 3" thick rim joist loaded perpendicular to grain.
2) Uplift loads have been increased 60% for wind and seismic loads; no further increase shall be permitted.
3) Minimum of (9) 16d nails per strap is required to meet IRC R 404.1.5.
4)
NAILS:
16d x 2-1/2 nails are 0.162" dia. x 2-1/2" long.
New products or updated product information are designated in
blue font
.
USP
Stock No. Ref. No.
Fastener
Schedule
1,4
Fastener
Schedule
1,4
Fastener
Schedule
1,4
130
Corrosion
Finish
Code
Ref.
DF/SP Allowable Loads (Lbs.)Dimensions (in)
2 x 142 x 8 2 x 10 2 x 12
Fastener
Schedule
1,4
TA51 PA51 2-1/16 48-1/4 17-5/8
TA71 PA68 2-1/16 68-1/4 22-1/8
Typical PA holdown
installation
TA
Installation:
• Use all specied fasteners. See Product Notes, page 17.
Allowable loads are based on either nail fastening or bolt fastening; nail and
bolt values cannot be combined.
Install by inserting product into footing’s wet concrete. All models require a
6" embedment into concrete foundations. Courses of concrete block must
be laid over connector. Notch mudsill at connector locations. Wrap strap over
rim joist and fasten.
Do not rely on these straps to secure concrete sections together between
cold joints; take other measures to transfer the load. If there is a cold joint
between block and foundation, the minimum embedment must be made into
the foundation.
Based on product embedment the exposed number of fastener holes may be
reduced. Using fewer fasteners will reduce allowable loads. Reduce allowable
loads by the code prescribed allowable load per fastener, for each fastener
not installed.
Allowable loads are based on a minimum concrete compressive strength of
2,500 psi at 28 days.
Bolts must be ordered separately. See page 24 for available sizes.
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Typical PA
purlin installation
Continued on next page
L
L1
W
2-1/4"
Holdowns