EWP Hangers
TFI / TFL / THO Top Mount Hangers
TFI & THO – Engineered for I-Joist to header applications. Offers full lateral
support of the I-Joist top chord, eliminating the need for web stiffeners in
most applications. Raised dimple nailing guides help assure correct 4
nailing into the I-Joist bottom ange. The THO’s feature the patented Seat
Cleat
®
that allows for quick, positive seating. The Seat Cleat
®
will hold the
I-Joist in place, eliminating spring back during nailing in the bottom ange.
TFL – Features 1-1/2" top ange depth that accommodates all header types
as well as back-to-back installations. Also features USP’s patented Seat
Cleat
®
for quick, positive seating.
Materials: See EWP Top Mount Hangers charts, pages 153-158.
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Patents: #5,564,248 – THO & TFL
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Refer to the top mount chart for applications requiring web stiffeners.
Requirements for web stiffener from the I-Joist manufacturer should be
followed, even if web stiffeners are not required in USP literature.
Uplift capacity for THO and TFL single ply hangers installed without joist
nails = 85 lbs. Refer to THO, TFL, & THF Single Ply I-Joist Hangers
Technical Bulletin.
Typical THO installation Typical TFL installation
THO
TFL
TFI
Qty Type Qty Type 100% 100%
2X 6 10d x 1-1/2 2 10d x 1-1/2 1270 140 1090 120
3X 6 16d x 2-1/2 2 10d x 1-1/2 1600 140 1375 120
(2) 2X 6 10d 2 10d x 1-1/2 1280 140 1100 120
4X 6 16d 2 10d x 1-1/2 1760 140 1515 120
2X 6 10d x 1-1/2 2 10d x 1-1/2 1360 360 1170 310
3X 6 16d x 2-1/2 2 10d x 1-1/2 1470 360 1265 310
(2) 2X 6 10d 2 10d x 1-1/2 1365 360 1175 310
4X 6 16d 2 10d x 1-1/2 1535 360 1320 310
2X 6 10d x 1-1/2 6 10d 1455 360 1250 310
3X 6 16d x 2-1/2 6 10d 2335 500 2010 430
(2) 2X 10 10d 6 10d 2370 500 2040 430
4X 10 16d 6 10d 2665 500 2290 430
4X 6 16d 2 10d x 1-1/2 2560 360 2200 310
4X 10 16d 2 10d x 1-1/2 3245 360 2790 310
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) Listed loads shall not be increased.
3)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long,
16d nails are 0.162" dia. x 3-1/2" long, 16d x 2-1/2 nails are 0.162" dia. x 2-1/2" long.
DF/ SP
Allowable Loads (Lbs.)
2
S-P-F
Allowable Loads (Lbs.)
2
THO
USP
Series
Nailer
Size
Fastener Schedule
3
Header Joist
TFL
THO
(Double)
TFI
Uplift
1
160%
Uplift
1
160%
Nailer Options
– chart represents maximum allowable loads for hangers used on wood
nailers. Reference page 140.
Slant Nailing
via dimple
nail holes
Diamond
holes
Seat Cleat
®
helps lock
I-Joist into place for
positive seating and
nailing ease.
H
D
D
W
W
D
W
2"
TF
1-1/2"
EWP Hangers
H
H
TF

Summary of content (7 pages)