Technical Specifications

148
© 2015 MiTek. All rights reserved.
EWP Hangers
SCL Charts Face Mount Hangers
Dimensions (in)
Uplift
1
Uplift
1
Joist Size Ref. No. W H D Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
HD414 MIU3.56/14 x 14 3-9/16 12-13/16 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650
THD414 -- -- x 14 3-5/8 12-7/8 3 58 16d 20 10d 7045 7045 7045 3905 5920 5920 5920 3235
THDH414 HGUS414 x 12 3-9/16 13-1/16 4 66 16d 16 16d 12510 12510 12510 6015 9920 10420 10510 5055
3-1/2 x 16 - 22 HD416 MIU3.56/16 x 14 3-9/16 14-13/16 2-1/2 26 16d 12 10d 3665 4215 4570 2285 3145 3620 3840 1980
3-1/2 x 18 - 26 HD418
MIU3.56/18,
MIU3.56/20
x 14 3-9/16 16-1/2 2-1/2 28 16d 8 10d 3950 4540 4570 1425 3390 3840 3840 1195
HD5210 -- -- x 14 5-3/8 7-7/8 2-1/2 18 16d 10 10d 2540 2920 3175 1905 2180 2505 2725 1650
HDQ5210IF HUCQ5.25/9-SDS x 14 5-1/4 9 3 12 WS3 6 WS3 5015 5590 5590 2975 3565 4100 4455 2500 31, R1, F32
THD610 HHUS5.50/10 x 12 5-1/2 9 3 38 16d 20 10d 6535 7255 7605 3410 5660 6295 6390 2865
THDH610
HGUS5.25/10,
HGUS5.50/10
x 12 5-1/2 9 4 46 16d 16 16d 8990 8990 8990 5400 7550 7550 7550 4535
HD5212 -- -- x 14 5-3/8 9-7/8 2-1/2 22 16d 10 10d 3100 3565 3880 1905 2660 3060 3330 1650
HDQ5212IF HUCQ5.25/11-SDS x 14 5-1/4 11 3 14 WS3 6 WS3 5605 5605 5605 3280 4160 4695 4695 2500 31, R1, F32
THD612 -- -- x 12 5-1/2 11 3 48 16d 20 10d 8255 8415 8415 4255 7070 7070 7070 3680
THDH612
HGUS5.25/12,
HGUS5.50/12
x 12 5-1/2 11 4 56 16d 20 16d 10365 10365 10365 5400 8705 8705 8705 4535
HD5214 -- -- x 14 5-3/8 11-7/8 2-1/2 24 16d 10 10d 3385 3890 4230 1905 2905 3340 3630 1650
THD614 -- -- x 12 5-1/2 12-7/8 3 58 16d 20 10d 8415 8415 8415 4255 7070 7070 7070 3680
THDH614 HGUS5.50/14 x 12 5-1/2 13 4 66 16d 22 16d 12510 12510 12510 6015 10510 10510 10510 5055
5-1/4 x 16 - 22 HD5216 -- -- x 14 5-3/8 13-7/8 2-1/2 30 16d 12 10d 4230 4570 4570 2285 3630 3840 3840 1980
6-3/4 x
9 - 14-1/2
THDH6710
HGUS210-4,
HGUS6.88/10
x 12 6-7/8 8-13/16 4 46 16d 12 16d 8990 8990 8990 4370 7550 7550 7550 3670
6-3/4 x 11 - 18 THDH6712
HGUS212-4,
HGUS6.88/12
x 12 6-7/8 10-13/16 4 56 16d 14 16d 8990 8990 8990 5225 7550 7550 7550 4390
6-3/4 x
13 - 20-1/2
THDH6714
HGUS214-4,
HGUS6.88/14
x 12 6-7/8 12-13/16 4 66 16d 16 16d 12510 12510 12510 6015 10510 10510 10510 5055
HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 1690 1945 2115 1140 1450 1670 1815 990
THD7210 HHUS7.25/10 x 12 7-1/4 9 3 38 16d 20 10d 6535 7255 7605 3410 5660 6295 6390 2865
THDH7210 HGUS7.25/10 x 12 7-1/4 9 4 46 16d 12 16d 8990 8990 8990 4370 7550 7550 7550 3670
HD7120 HU412-2 x 14 7-1/8 10-5/8 2-1/2 16 16d 6 10d 2255 2595 2820 1140 1935 2225 2420 990
THDH7212 HGUS7.25/12 x 12 7-1/4 10-1/2 4 56 16d 14 16d 8990 8990 8990 5225 7550 7550 7550 4390
HD7140 HU414-2 x 14 7-1/8 13 2-1/2 20 16d 8 10d 2820 3245 3525 1525 2420 2785 3025 1320
THDH7214 HGUS7.25/14 x 12 7-1/4 12-1/4 4 66 16d 16 16d 12510 12510 12510 6015 10510 10510 10510 5055
7 x 16 - 22 HD7160 -- -- x 14 7-1/8 15-5/8 2-1/2 24 16d 8 10d 3385 3890 4230 1525 2905 3340 3630 1320
7 x 18 - 26 HD7180 -- -- x 14 7-1/8 17-3/4 2-1/2 28 16d 8 10d 3950 4540 4570 1525 3390 3840 3840 1320
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Minimum nail
p
enetration shall be 1-1/2" for 10d nails and 1-5/8" for 16d nails.
3
)
WS3 Wood Screws are 1/4" x 3" and are included with HDQ han
g
ers.
4
)
NAILS: 10d nails are 0.148" dia. x 3" lon
g,
16d nails are 0.162" dia. x 3-1/2" lon
g
.
Load tables address han
g
er/header/fastener limitations onl
y
. Joist limitations must be determined for each installation.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
7 x 14 - 20
7 x 11-1/4 - 16
7 x 9-1/4 - 14
5,
F2,
R5
5-1/4 x
11-1/4 - 16
5,
F2,
R5
5-1/4 x 14 - 20
Header
5-1/4 x
9-1/4 - 11-7/8
Joist
USP
Stock No.
Code
Ref.
3-1/2 x 14 - 20
5,
F2,
R5
Web
Stiff
Reqd Ga
Fastener Schedule
2,3,4
DF/SP Header
Allowable Loads (Lbs.)
S-P-F Header
Allowable Loads (Lbs.)
EWP Hangers
H
W
D