Technical Specifications

130
Hangers
© 2015 MiTek. All rights reserved.
TUS – For a single ply purlin.
DTUS – For a single ply purlin with a 2-ply
saddle dimension.
Materials: 20 gauge
Finish: G90 galvanizing
Codes: See page 11 for Code Reference Chart
Patents: Pending
Installation:
Use all specied fasteners. See Product
Notes, page 17.
Attaches with standard 1-1/2" joist hanger
nails that can be installed with a positive
placement nail gun or be hand driven.
Other 1-1/2" fasteners with a shear value
equal or greater than a 10d nail may be used.
TUS / DTUS Undersaddle Hangers
Uplift
1
F2
W H Face Bottom Type Face Bottom Type 100% 115% 125% 160% 160%
8d x 1-1/2 8d x 1-1/2 480 545 590 505 205
10d x 1-1/2 10d x 1-1/2 570 620 620 505 205
LL915 LL915 570 620 620 505 205
8d x 1-1/2 8d x 1-1/2 480 545 590 505 645
10d x 1-1/2 10d x 1-1/2 570 620 620 505 645
LL915 LL915 570 620 620 505 645
8d x 1-1/2 8d x 1-1/2 480 545 590 505 645
10d x 1-1/2 10d x 1-1/2 570 620 620 505 645
LL915 LL915 570 620 620 505 645
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) LL915 screws are #9 (0.131" diameter) x 1-1/2" long.
3) NAILS: 8d x 1-1/2" nails are 0.131" dia. x 1-1/2" long, 10d x 1-1/2" nails are 0.148" dia. x 1-1/2" long, LL915 screws are #9 (0.131" dia.) x 1-1/2" long.
DF/SP
Allowable Loads (Lbs.)
1
Dimensions
(in)
Code
Ref.
1-9/16 3
Fastener Schedule
2,3
1-9/16 3
Header
Qty
Joist
Qty
1 41
130
DTUS24 -- -- 20 1-9/16
4 1 41
4
1
Joist
Size Ref. No.
Steel
Gauge
USP
Stock No.
2 x 4 - 6
Single
TUS24S -- -- 20
2 x 4 - 6
Saddle
34 1 4
TUS24 -- -- 20
Typical DTUS24
installation
DTUS24TUS24
Bottom
View
Typical TUS24
installation
Uplift
F2
F2
TUS24S
H
W
W
W
H
3-1/4"
H
W
W
Hangers