Use and Care Manual

138
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Lumber Hangers
Lumber Hangers
MiTek
®
Product Catalog
Hanger
Type
MiTek
USP
Series
Steel
Gauge
Formed
Welded
Masonry
100%
DF/SP
100%
JL 20 •• -- 470 - 1,960
139, 142-143,
154-155
FB 18 •• -- 315 - 330 184
JUS 18 ••• -- 675 - 2,420
140, 142-150,
154-162
CSH 18 •• -- 890 181
MUS 18 •••• -- 1,285 - 1,710
140, 142-143,
154-155
JLIF 18 ••• -- 465 - 1,520
139, 142-143,
154-155
SUH 16 •• -- 500 - 2,645
139, 142-151,
153-163, 165
16
14
HD 14 •••• -- 615 - 4,620 141-165
ADTT 14 ••• --
790 - 850
1
182
DTB 14 --
1835
1
183
HDQIF 14 •• •••• -- 3,340 - 5,605
141, 144-152,
156-164
FWH 14 ••••• •••• -- 2,045 - 2,980 194-195
FWHBP 12 •••• -- 5,695 - 8,015 196-197
FWHFM 12 •••• -- 5,960 200-201
FWHH 12 •• -- 6, 005 - 7,355 198-199
HL 18 ••• -- 1,255 - 1,490 166, 169
JH 18 •• -- 1,910 - 2,555 172
KLB 14 •• -- 1,670 - 2,140 166, 169
KB 12 ••• -- 4,075 - 4,795 166, 170-171
HDO 12 ••• -- 2,405 - 5,845 167, 169-171
SW 12 •• •• -- 2,315 - 2,520 168-170
SWH
7 -
Top Flange;
12 - Stirrup
•• ••• -- 3,305 168-171
KHW
3 -
Top Flange;
10 - Stirrup
•• ••• -- 5,295 - 5,535 168, 170-171
RR 18 -- 365 - 380 173
LS 18 •• ••--840 - 1,285 173
18
16
16
14
SKHH 14 •• ••• -- 1,765 - 4,005 175-176
JPF 20 •• -- 1,035 178
DTUS 20 •• -- 485 - 580 180
TUS 20 •• -- 485 - 580 180
KF 18 ••• -- 695 - 810 177
PHG 18 ••• -- 580 - 650 177
FHD 18 •• -- 960 181
JDS 18 ••• -- 480 - 1,675 179
HD 14 •• •••• 335 - 5750 -- 186
MPH 12
••••
2,585 - 4,280 -- 188-189
LGUM 12
•••
6,065 - 9,905 -- 187
HGUM 7
•••
16,680 -- 187
HWUH
1/4" -
Top Flange;
7 - Stirrup
•• •••
3,060 - 5,265 -- 190-191
UMH 1/4"
•••
3,550 - 6,380 -- 185
NFM
3/8" -
Top Flange;
7 - Stirrup
•••
6,720 - 10,310 -- 192-193
• Re
p
resents common a
pp
lications and
p
roduct confi
g
urations. Consult MiTek for additional a
pp
lications and/or o
p
tional
p
roduct confi
g
urations.
1
)
Allowable loads reflect DF/SP Tension 160%.
2
)
When an I-Joist is used as a header
,
desi
g
ner must evaluate if a web stiffener or backer block is re
q
uired.
New products or updated product information are designated in blue font.
-- 510 - 3,170
MiTek USP Series
Catalog Page Reference
140, 142-145,
149-150, 154-
157, 161-162
174
175-176
Allowable Loads (Lbs.)
Range
Header Material
850 - 5,580
Stringer
620 - 2,645
--
--
••
•••
Masonry
Slope
and
Skew
Panel
and
Purlin
SKH
Top
Mount
Face
Mount
LSSH
HUS
Fire
Wall
••
•• ••
••
Rim Joist
••
Style
I-Joist
Truss (2x)
Floor Truss 4x
Glulam
Beam/Joist/Rafter
(rect shapes)
Beam/Joist/Rafter
(rect shapes)
Supported /
Joist Member
Supporting /
Header Member
Truss (2x)
Floor Truss 4x
Nailer
Wall
Post
Glulam
I-Joist
Hanger Selector Guide
Represents common
applications and product
congurations. Consult
MiTek for additional
applications and/or optional
product congurations.
1) Allowable loads reect
DF/SP Tension 160%.
2) When an I-Joist is used as
a header, designer must
evaluate if a web stiffener or
backer block is required.
New products or updated
product information are
designated in blue font.