W1 W2 H1 H2 D A 100% 115% 125%
3-1/2 x 9-1/4 FWHFM35925 9-1/16 13-9/16
3-1/2 x 9-1/2 FWHFM3595 9-5/16 13-13/16
3-1/2 x 11-7/8 FWHFM35118 11-11/16 16-3/16
3-1/2 x 14 FWHFM3514 13-13/16 18-5/16
3-1/2 x 16 FWHFM3516 15-13/16 20-5/16
3-1/2 x 18 FWHFM3518 17-13/16 22-5/16
3-1/2 x 20 FWHFM3520 19-13/16 24-5/16
3-1/2 x 22 FWHFM3522 21-13/16 26-5/16
3-1/2 x 24 FWHFM3524 23-13/16 28-5/16
4 - 4-3/16 x 9-1/4 FWHFM42925 9-1/16 13-9/16
4 - 4-3/16 x 9-1/2 FWHFM4295 9-5/16 13-13/16
4 - 4-3/16 x 11-7/8 FWHFM42118 11-7/16 15-15/16
4 - 4-3/16 x 14 FWHFM4214 13-5/8 18-1/8
4 - 4-3/16 x 16 FWHFM4216 15-5/8 20-1/8
4 - 4-3/16 x 18 FWHFM4218 17-5/8 22-1/8
4 - 4-3/16 x 20 FWHFM4220 19-5/8 24-1/8
4 - 4-3/16 x 22 FWHFM4222 21-5/8 26-1/8
4 - 4-3/16 x 24 FWHFM4224 23-5/8 28-1/8
5-1/4 x 9-1/4 FWHFM52925 9-1/16 13-9/16
5-1/4 x 9-1/2 FWHFM5295 9-5/16 13-13/16
5-1/4 x 11-7/8 FWHFM52118 11-5/8 16-1/8
5-1/4 x 14 FWHFM5214 13-13/16 18-5/16
5-1/4 x 16 FWHFM5216 15-13/16 20-5/16
5-1/4 x 18 FWHFM5218 17-13/16 22-5/16
5-1/4 x 20 FWHFM5220 19-23/28 24-5/16
5-1/4 x 22 FWHFM5222 21-13/16 26-5/16
5-1/4 x 24 FWHFM5224 23-13/16 28-5/16
7 x 11-7/8 FWHFM71118 11-11/16 16-3/16
7 x 14 FWHFM7114 13-13/16 18-5/16
7 x 16 FWHFM7116 15-13/16 20-5/16
7 x 18 FWHFM7118 17-13/16 22-5/16
7 x 20 FWHFM7120 19-13/16 24-5/16
7 x 22 FWHFM7122 21-13/16 26-5/16
7 x 24 FWHFM7124 23-13/16 28-5/16
1) Download allowable load is for attachment to the wide face of a supporting column.
2) Uplift loads have been increased 60% for wind or seismic loads. No further increase shall be permitted.
3) Distance from the supported member to the edge of the header support flange is 9/16".
4)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
10d x 1-1/2 5960 662510d 18
40 10d 18
Joist
Type Type
DF/SP
Allowable Loads (Lbs.)
Qty
Joist
Size (in)
MiTek USP
Stock No.
Ref.
No.
Steel
Gauge
Face
Qty
Uplift
160%
2
Dimensions (in)
Fastener Schedule
3
-- 12 3-9/16 4-11/16
6625
10d x 1-1/2 59602 2-1/16
-- 12 4-3/16 5-5/16 2 2-3/8 40
Download
1
7050 2990
6085 6085 2990
5960
5960
6625 7050 2990
7050 2990
-- 12 5-3/8 2 36-1/2
-- 12 7-1/8 28-1/4 3-7/8 40 10d 18
10d x 1-1/240 10d 18
10d x 1-1/2
FWHFM Fire Wall Hangers for Face Mount Applications
Option
Skewed
1
Range
1˚ to 70˚
Allowable Loads
70% of table load
1) Skewed hangers with skews greater than 15° may have all
joist nailing on outside flange.
Ordering
Add
SK,
angle required, right
(R)
or left
(L),
and square cut
(SQ)
to product number.
Ex. FWHFM5214_SK60L_SQ