Use and Care Manual

Truss & Rafter
253
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Truss & Rafter
MiTek
®
Product Catalog
Ref. No. Qty Type
5,6
Qty Screw Anchor
3
LUGT2 LGT2 14 2 16 10d 5 1/4" x 3" 1655 1015 475 1460 790 475
LUGT3 LGT3-SDS2.5 12 3 12 WS25 4 3/8" x 5" 3380 -- -- 3380 -- --
LUGT4 LGT4-SDS3 12 4 16 WS3 4 3/8" x 5" 3380 -- -- 3380 -- --
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Additional anchora
g
e
p
roducts to be desi
g
ned b
y
others.
3
)
Use DeWalt Screw-Bolt
TM
+ 1/4" dia. x 3" or 3/8" dia. x 5" screw anchors
;
or e
q
ual
,
installed in accordance with manufacturer's s
p
ecification.
Screw Anchors must be ordered se
p
eratel
y
, see
p
a
g
e 44 for anchor information.
4
)
Fasteners must be installed in full
y
g
routed and reinforced concrete masonr
y
(
f'm = 1,500
p
si
)
or reinforced concrete
(
f'c = 2,500
p
si
)
.
5
)
MiTek's WS25 structural wood screws are 1/4" dia. x 2-1/2" lon
g
(
su
pp
lied with LUGT3
)
and WS3 structural wood screws
are 1/4" dia. x 3" lon
g
(
su
pp
lied with LUGT4
)
.
6
)
NAILS: 10d nails are 0.148" dia. x 3" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
Concrete/Masonry Installation
--
S-P-F
Allowable Loads (Lbs.)
1
Uplift
160%
Fastener Schedule
2
MiTek USP
Stock No.
Steel
Gauge
No.
of
Plies
DF/SP
Allowable Loads (Lbs.)
1
CMU/Concrete
Wall
4
Rafter/Truss
Uplift
160%
F1
160%
F2
160%
F1
160%
F2
160%
Code
Ref.
LUGT Girder Tiedowns
LUGT2
LUGT4
Typical LUGT2
masonry installation
Typical LUGT4
masonry installation
(LUGT3 similar)
LUGT3
The LUGT series is an adaptable tiedown for girder trusses
and offers several installation options to accommodate
different framing conditions. It is an ideal retrot solution to
reinforce truss connections to transfer high wind loads to
supporting walls and can be used on either concrete or CMU
block walls. Sizes available for 2-ply, 3-ply and 4-ply trusses.
Materials: See chart
Finish: G90 galvanizing
Installation:
• Use all specied fasteners. See Product Notes, page 18.
All large fastener holes must be lled with specied
fasteners to achieve loads listed in the chart. Smaller
fastener holes are for girder-to-stud applications
(reference page 257) and do not need to be lled when
used for concrete/masonry installations.
MiTek’s WS structural wood screws are included with
LUGT3 and LUGT4.
For concrete and masonry applications,
a moisture barrier may be required, check
local building code.
15-15/16"
11-1/8"
5"
4-3/4"
16-1/8"
12-7/8"
6-9/16"
6-1/4"
12-7/8"
3"
6-3/4"
3-1/4"
F1
F1
F2
F2
Uplift
F1
F1
F2
F2
Uplift