Face Mount Hangers – DF/SP Allowable Loads
Floor
Uplift
1
Joist Size Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160%
JUS46 LUS46 18 3-5/8 5 2 1 -- 4 16d 4 16d 1040 1185 1290 1270
10d 1250 1405 1515
16d 1470 1670 1800
HUS46 HUS46 14 3-5/8 5 2 1 -- 4 16d 4 16d 1085 1235 1330 1170
HUS46IF HUSC46 14 3-5/8 5 2 1 -- 4 16d 4 16d 1085 1235 1330 1170
Min 8 4 1230 1390 1490 760
Max 12 6 1850 2085 2235 1170
Min 8 4 1230 1390 1490 760
Max 12 6 1850 2085 2235 1170
JUS46 LUS46 18 3-5/8 5 2 1 -- 4 16d 4 16d 1040 1185 1290 1270
JUS48 LUS48 18 3-5/8 6-7/8 2 1 -- 6 16d 4 16d 1325 1510 1645 1270
10d 1250 1405 1515
16d 1470 1670 1800
HUS46 HUS46 14 3-5/8 5 2 1 -- 4 16d 4 16d 1085 1235 1330 1170
HUS46IF HUSC46 14 3-5/8 5 2 1 -- 4 16d 4 16d 1085 1235 1330 1170
HUS48 HUS48 14 3-5/8 7 2 1 -- 6 16d 6 16d 1625 1850 1880 2420
HUS48IF HUSC48 14 3-5/8 7 2 1 -- 6 16d 6 16d 1625 1850 1880 2420
Min 8 4 1230 1390 1490 760
Max 12 6 1850 2085 2235 1170
Min 8 4 1230 1390 1490 760
Max 12 6 1850 2085 2235 1170
Min 10 4 1540 1735 1865 780
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 780
Max 14 6 2155 2430 2610 1170
JUS48 LUS48 18 3-5/8 6-7/8 2 1 -- 6 16d 4 16d 1325 1510 1645 1270
JUS410 LUS410 18 3-5/8 8-7/8 2 1 -- 8 16d 6 16d 1845 2105 2290 2345
10d 2000 2245 2420
16d 2350 2670 2880
HUS48 HUS48 14 3-5/8 7 2 1 -- 6 16d 6 16d 1625 1850 1880 2420
HUS48IF HUSC48 14 3-5/8 7 2 1 -- 6 16d 6 16d 1625 1850 1880 2420
Min 10 4 1540 1735 1865 780
Max 14 6 2155 2430 2610 1170
Min 10 4 1540 1735 1865 780
Max 14 6 2155 2430 2610 1170
HUS410 HUS410 14 3-5/8 8-7/8 2 1 -- 8 16d 8 16d 2170 2465 2660 2420
HUS410IF HUSC410 14 3-5/8 8-7/8 2 1 -- 8 16d 8 16d 2170 2465 2660 2420
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1950
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1950
HDQ410IF HUCQ410 14 3-9/16 9 3 1-1/2 -- 12 WS3 6 WS3 5015 5590 5590 2975
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
For JUS and HUS han
g
ers: Nails must be driven at a 30° to 45˚ an
g
le throu
g
h the
j
oist or truss into the header to achieve the table loads.
3
)
MiTek's WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with HDQIF han
g
ers.
4
)
NAILS: 10d nails are 0.148" dia. x 3" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
--
8-13/16
8-13/16
2-1/2
HD410IF HUC410 14 3-9/16 2-1/2
2-1/2 --
HD410 HU410 14 3-9/16 1-1/8
HD48IF HUC48 14 3-9/16 6-15/16
14 3-9/16 6-15/16 2-1/2 1-1/8
6-15/16 2-1/2 1-1/8
14 3-9/16 6-15/16 2-1/2 --
14 3-9/16
3-9/16 8-3/8 2 1-1/8
4 x 6
4 x 8
--
--
--
3-9/16 4-13/16 2 1-1/8
3-9/16 5-1/16 2-1/2 1-1/8
HD46IF HUC46 14 3-9/16
4 x 10
HD46 HU46 14 3-9/16
HD48 HU48
HD48 HU48
HD46IF HUC46 14 3-9/16
HD48IF HUC48
Dimensions (in)
MiTek USP
Stock No.
Steel
Gauge
16 SUH410 U410
16
16
14
U46 SUH46
HD46 HU46
SUH46 U46
--
3-9/16 4-13/16 2 1-1/8
Roof
Min/
Max
5-1/16 2-1/2 --
10
16d 10d
5-1/16 2-1/2 1-1/8
16d 10d
5-1/16 2-1/2
16 6 10d
10d
16d 10d
10d16d
16d 10d
16d
Code
Ref.
Corrosion
Finish
Header Joist
DF/SP
Allowable Loads (Lbs.)
2
Fastener Schedule
3,4
IBC,
FL,
LA
1135
4 10d 755
10 4 10d 755
16d 10d
16d 10d
16d 10d
16d 10d
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
A
D
H
W