Use and Care Manual

Lumber Hangers
163
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Lumber Hangers
MiTek
®
Product Catalog
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Floor
Uplift
1
Joist Size Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160%
Min 18 8 2440 2750 2950 1205
Max 26 12 3520 3860 3860 2060
Min 18 8 2440 2750 2950 1205
Max 26 12 3520 3860 3860 2060
Min 22 10 2980 3360 3605 1715
Max 30 14 4015 4015 4015 1805
Min 22 10 2980 3360 3605 1715
Max 30 14 4015 4015 4015 1805
HD418 -- 14 3-9/16 16-1/2 2-1/2 1-1/4 -- 28 16d 8 10d 3795 3835 3835 1375
10d 880 990 1065
16d 1035 1175 1265
Min 8 4 1085 1220 1310 685
Max 12 6 1625 1835 1965 1035
Min 8 4 1085 1220 1310 685
Max 12 6 1625 1835 1965 1035
10d 880 990 1065
16d 1035 1175 1265
Min 8 4 1085 1220 1310 685
Max 12 6 1625 1835 1965 1035
Min 8 4 1085 1220 1310 685
Max 12 6 1625 1835 1965 1035
Min 10 4 1355 1525 1640 760
Max 14 6 1895 2140 2295 1035
Min 10 4 1355 1525 1640 760
Max 14 6 1895 2140 2295 1035
10d 1540 1730 1865
16d 1810 2055 2215
Min 10 4 1355 1525 1640 760
Max 14 6 1895 2140 2295 1035
Min 10 4 1355 1525 1640 760
Max 14 6 1895 2140 2295 1035
Min 14 6 1895 2140 2295 1035
Max 20 10 2710 3055 3275 2025
Min 14 6 1895 2140 2295 1035
Max 20 10 2710 3055 3275 2025
HDQ610IF HUCQ610 14 5-1/2 9 3 1-1/8 -- 12 WS3 6 WS3 4670 4885 4885 2855
10d 1540 1730 1865
16d 1810 2055 2215
Min 14 6 1895 2140 2295 1035
Max 20 10 2710 3055 3275 2025
Min 14 6 1895 2140 2295 1035
Max 20 10 2710 3055 3275 2025
HDQ610IF HUCQ610 14 5-1/2 9 3 1-1/2 -- 12 WS3 6 WS3 4670 4885 4885 2855
Min 16 8 2165 2445 2620 1035
Max 24 12 3250 3665 3930 2430
Min 16 8 2165 2445 2620 1035
Max 24 12 3250 3665 3930 2430
HDQ612IF HUCQ612 14 5-1/2 11 3 1-1/2 -- 14 WS3 6 WS3 4960 4960 4960 2770
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
MiTek's WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with HDQIF han
g
ers.
3
)
NAILS: 10d nails are 0.148" dia. x 3" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
16d 16d
16d 16d
16d 16d
16d 16d
16d 16d
16d 16d
16d 16d
16d 16d
16d 16d
5-1/2 9-13/16 2-1/2 1-1/8
HD610IF HUC610 14 5-1/2 7-13/16
HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8
HD68IF HUC68 14 5-1/2 5-15/16
5-1/2 9 2
HU66 14 5-1/2 4-1/16 2-1/2 1-1/8
2-1/2 --
HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8
HD66IF HUC66 14 5-1/2 4-1/16
16d 10d--
Dimensions (in)
SPF
Allowable Loads (Lbs.)
2
Corrosion
Finish
Header Joist
14-13/16
12-13/16 2-1/2
14-13/16
3-9/16 12-13/16 2-1/2 1-1/8
2-1/2 1-1/8 16d 10d
16d 10d2-1/2 --
HD414 HU414 14
MiTek USP
Stock No.
Steel
Gauge
Roof
Code
Ref.
Min/
Max
Fastener Schedule
3
16d 10d
IBC,
FL,
LA
14 5-1/2
14 3-9/16
HUC414 14 3-9/16
HU416 14 3-9/16
HUC416
16d 16d 6 x 6
6 x 8
1
1
SUH66 U66 16 5-1/2 5
SUH66 U66 16 5-1/2 5
2
2
HD66 HU66 14 4-1/16
HD66IF HUC66
16d
--
--
--
--
2-1/2 1-1/85-1/2
2-1/2 --
2-1/2 --
5-1/2 5-15/16
2-1/2 --
4-1/16
5-1/2 7-13/16
7-13/16 2-1/2 1-1/8
14
1
2-1/2 --
HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8
HD610IF HUC610 14
HD612IF HUC612 14 5-1/2 9-13/16
2-1/2 --
HD612 HU612 14
16d
4 x 18
6 x 12
SUH610 U610 16 5-1/2 9 2
1
6 x 10
SUH610 U610 16
2-1/2 --
HD610 HU610 14 5-1/2
HD414IF
HD416
HD68IF HUC68
HD416IF
HD66
14 6 10d 970
6654 10d8
8 4 10d 665
14 6 10d 970
16d 16d
16d 16d
16d
16d
Face Mount Hangers – SPF Allowable Loads
A
D
H
W
Continued on next page