Lumber Hangers
Lumber Hangers
MiTek
®
Product Catalog
LSSH Slope/Skew Hangers
Typical LSSH179-TZ
installation
LSSH35-TZ
The LSSH series connects rafters to ridge beams in vaulted roof
structures. This series is eld adjustable to meet a variety of skew
and/or slope applications. Slopes and skews 0° to 45°.
Materials: See chart
Finish: G-185 galvanizing
Options: See Chart for Corrosion Finish Options
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Steps:
1. Position LSSH connector against plumb-cut end of joist.
Fasten joist side anges on both sides with 10d (0.148") x 1-1/2"
HDG nails. Bend seat up to t against joist bottom and drive
(1) 10d (0.148") x 1-1/2" HDG nail through bottom seat into
rafter bottom. Drive (2) 10d (0.148") x 1-1/2" HDG nails at
downward angle through dimpled nailing guides.
2. Lean connector and rafter end against ridge beam at desired
position. Install specied 10d (0.148" dia. x 3") HDG or 16d
(0.162 x 3-1/2") HDG nails through nail holes into ridge beam
at right 90° angle. If skewing the rafter, only drive nails into
ridge beam on inside ange.
3. Bend ange to desired angle.
4. Hammer outside ange until edge touches header. Fasten outside
ange to ridge by driving specied 10d (0.148" dia. x 3") HDG or
16d (0.162 x 3-1/2") HDG nails through nail holes.
Web stiffeners are required for all wood I-Joist installations.
Designer may consider adding a tension restraint for the supported
member for roof slopes exceeding 6/12. Refer to page 122.
Skew to 45° maximum
2
3 & 4
1
LSSH15-TZ = 5-1/16"
All other sizes = 8-7/8"
W2 W1 W2
3"
Slope to 45° up
or down
LSSH210-TZ
W2
W1
W2
3"
Slope to 45°
up or down
8-7/8"
Floor
Uplift
1
Floor
Uplift
1
Ref. No. W1 W2 Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
1-1/2 LSSH15-TZ
LSSJ26LZ, LSSJ26RZ,
LSSJ28LZ, LSSJ28RZ
18 1-9/16 1-3/4 6 10d HDG 7 10d x 1-1/2 HDG 720 820 885 565 640 730 785 440
1-1/2 LSSH210-TZ LSSJ210LZ, LSSJ210RZ 18 1-9/16 1-3/4 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 410 1065 1090 1090 320
1-3/4 LSSH179-TZ LSSR1.81Z 18 1-13/16 1-5/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
2 - 2-1/8 LSSH20-TZ LSSR2.1Z 18 2-1/8 2-1/2 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 795 1065 1085 1085 620
2-1/4 - 2-5/16 LSSH23-TZ LSSR2.37Z 18 2-5/16 2-3/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 795 1065 1085 1085 620
2-1/2 LSSH25-TZ LSSR2.56Z 16 2-9/16 2-3/4 18 16d HDG 12 10d x 1-1/2 HDG 2095 2095 2095 945 1640 1640 1640 740
2-5/8 LSSH26-TZ -- 16 2-11/16 2-5/8 18 16d HDG 12 10d x 1-1/2 HDG 2095 2095 2095 945 1640 1640 1640 740
3 LSSH31-TZ LSSR210-2Z 16 3-1/8 3-3/4 18 16d HDG 12 10d x 1-1/2 HDG 2645 3000 3090 1310 2345 2415 2415 1025
3-1/2 LSSH35-TZ LSSR410Z 16 3-9/16 3-1/2 18 16d HDG 12 10d x 1-1/2 HDG 2645 3000 3090 1310 2345 2405 2405 1020
1-1/2 LSSH15-TZ
LSSJ26LZ, LSSJ26RZ,
LSSJ28LZ, LSSJ28RZ
18 1-9/16 1-3/4 6 10d HDG 7 10d x 1-1/2 HDG 620 620 620 510 485 485 485 400
1-1/2 LSSH210-TZ LSSJ210LZ, LSSJ210RZ 18 1-9/16 1-3/4 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
1-3/4 LSSH179-TZ LSSR1.81Z 18 1-13/16 1-5/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
2 - 2-1/8 LSSH20-TZ LSSR2.1Z 18 2-1/8 2-1/2 10 10d HDG 7 10d x 1-1/2 HDG 1200 1230 1230 795 960 960 960 620
2-1/4 - 2-5/16 LSSH23-TZ LSSR2.37Z 18 2-5/16 2-3/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1230 1230 795 955 955 955 620
2-1/2 LSSH25-TZ LSSR2.56Z 16 2-9/16 2-3/4 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 945 1260 1260 1260 740
2-5/8 LSSH26-TZ -- 16 2-11/16 2-5/8 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 945 1260 1260 1260 740
3 LSSH31-TZ LSSR210-2Z 16 3-1/8 3-3/4 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 1310 1260 1260 1260 1025
3-1/2 LSSH35-TZ LSSR410Z 16 3-9/16 3-1/2 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 1310 1255 1255 1255 1020
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
.
2) Stainless steel ring shank nails must be used with stainless steel connectors to achieve tabulated allowable loads
.
3) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long.
IBC,
FL,
LA
IBC,
FL,
LA
Rafter
Width (in)
Dimensions
(in)
Code
Ref.
SLOPED ONLY HANGER
S
SKEWED HANGERS or SLOPED & SKEWED HANGERS
MiTek
Stock No.
Steel
Gauge
Roof Roof
Corrosion
Finish
Fastener Schedule
2,3
Header Rafter
DF/SP
Allowable Loads (Lbs.)
S-P-F
Allowable Loads (Lbs.)
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc