LGUM / HGUM Masonry Girder Hangers
LGUM and HGUM Masonry Girder Hangers are high-capacity beam/
girder hangers designed for installation to masonry or concrete walls.
The LGUM and HGUM hangers use MiTek’s WS structural wood screws
(supplied) to attach the beam to hanger and screw anchors (supplied)
to attach to the masonry or concrete wall. These hangers eliminate the
need for constructing beam pockets.
Materials: LGUM – 12 gauge; HGUM – 7 gauge
Finish: G90 galvanizing
Options: See Specialty Options chart
Installation:
MiTek’s WS3 structural wood screws and screw anchors are supplied
with hangers. Substituting other fasteners may reduce capacity.
Beams comprised of multiple plies must be adequately fastened
to act as a single member.
Beam height dimension (H) must be specied when ordering
HGUM hangers.
Moisture barrier between beam and wall may be required
by local jurisdiction.
Ref. No. W H
3
D
A
Qty Qty
LGUM26-2 LGUM26-2-SDS 12 3-5/16 5-7/16 4 2-3/8 4 3/8" x 4" 4 WS3 6065 6425 2125 2125
LGUM28-2 LGUM28-2-SDS 12 3-5/16 7-3/16 4 2-3/8 6 3/8" x 4" 6 WS3 8155 8155 2770 2770
LGUM210-2 LGUM210-2-SDS 12 3-5/16 9-3/16 4 2-3/8 8 3/8" x 4" 8 WS3 9905 9905 3350 3350
LGUM26-3 LGUM26-3-SDS 12 4-15/16 5-1/2 4 2-3/8 4 3/8" x 4" 4 WS3 6065 6425 2125 2125
LGUM28-3 LGUM28-3-SDS 12 4-15/16 7-1/4 4 2-3/8 6 3/8" x 4" 6 WS3 8155 8155 2770 2770
LGUM210-3 LGUM210-3-SDS 12 4-15/16 9-1/4 4 2-3/8 8 3/8" x 4" 8 WS3 9905 9905 3350 3350
LGUM26-4 LGUM26-4-SDS 12 6-9/16 5-7/16 4 2-3/8 4 3/8" x 4" 4 WS3 6065 6425 2125 2125
LGUM28-4 LGUM28-4-SDS 12 6-9/16 7-3/16 4 2-3/8 6 3/8" x 4" 6 WS3 8155 8155 2770 2770
LGUM210-4 LGUM210-4-SDS 12 6-9/16 9-3/16 4 2-3/8 8 3/8" x 4" 8 WS3 9905 9905 3350 3350
LGUM46 LGUM46-SDS 12 3-5/8 4-7/8 4 2-3/8 4 3/8" x 4" 4 WS3 6065 6425 2125 2125
LGUM48 LGUM48-SDS 12 3-5/8 6-7/8 4 2-3/8 6 3/8" x 4" 6 WS3 8155 8155 2770 2770
LGUM410 LGUM410-SDS 12 3-5/8 8-7/8 4 2-3/8 8 3/8" x 4" 8 WS3 9905 9905 3350 3350
HGUM525 HGUM5.25-SDS 7 5-1/4 5-1/2 4-3/4 8 5/8" x 5" 24 WS3 16680 16680 4470 10130
HGUM550 HGUM5.50-SDS 7 5-1/2 5-1/2 4-3/4 8 5/8" x 5" 24 WS3 16680 16680 4470 10130
HGUM700 HGUM7.00-SDS 7 7 5-1/2 4-3/4 8 5/8" x 5" 24 WS3 16680 16680 4470 10130
HGUM725 HGUM7.25-SDS 7 7-1/4 5-1/2 4-3/4 8 5/8" x 5" 24 WS3 16680 16680 4470 10130
HGUM900 HGUM9.00-SDS 7 9 5-1/2 4-3/4 8 5/8" x 5" 24 WS3 16680 16680 4470 10130
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Allowable loads assume to
p
header fasteners are a minimum of 4" from the to
p
of the wall.
3
)
"S
p
ecif
y
" denotes the re
q
uired su
pp
orted beam hei
g
ht that must be s
p
ecified at the time of orderin
g
.
4
)
Use DeWalt Screw-Bolt
TM
+
(
included
);
or e
q
ual
,
installed in accordance with manufacturer's s
p
ecification.
5
)
MiTek's WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with han
g
ers.
Dimensions (in.) Fastener Schedule
DF Allowable Loads (Lbs.)
2
Type
5
Uplift (160%)
1
4" Min. to
Top of Wall
CMU
1,500psi
Concrete
2,000 psi
Download
(100/115/125%)
JoistCMU/Concrete
CMU / Concrete
Code
Ref.
--
Double 2x Sizes
Specify
11-1/4
to
30
Engineered Wood & Structural Lumber Sizes (Heavy Duty)
4x Sizes
Quadruple 2x Sizes
Triple 2x Sizes
MiTek USP
Stock No.
Steel
Gauge
13" Min. to
Top of Wall
Screw
Anchor
4
Typical HGUM
installation
Typical LGUM
installation
Min. 4"
distance to
top of wall
(13" min for
max uplift)
HGUM LGUM
W
W
D
A
1"
3/4"
A
D
H
Specify
(Min=11-1/4")
Option Inverted Flange
Range One Inverted-Flange option available
50% of table download
75% of table uplift load
Ordering
Add
IF
and right
(R)
or left
(L)
to product number.
Ex. HGUM525_H=18_IFL
Allowable
Loads
Typical HGUM
one inverted ange, left shown
Specialty Options Chart – Refer to Specialty Options pages 320-321 for additional details.