Use and Care Manual

EWP Hangers
207
MiTek
®
Product Catalog
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
EWP Hangers
THF Face Mount I-Joist Hangers
Option
Skewed
1,3
Sloped Seat
2,3
Sloped / Skewed
1,2,3
Inverted Flange
1
)
Skewed han
g
ers with skews
g
reater than 15° ma
y
have all
j
oist nailin
g
on outside flan
g
e.
2
)
Slo
p
ed or slo
p
ed / skewed han
g
ers with slo
p
es
g
reater than 15° ma
y
have additional
j
oist nails.
3
)
For skewed han
g
ers, the re
q
uired cut t
yp
e
(
s
q
uare or bevel
)
of
j
oist member ma
y
var
y
based on skew an
g
le
and width of han
g
er. Some s
q
uare cut han
g
ers will re
q
uire custom
p
ricin
g
due to welded back
p
late.
Range
Allowable
Loads
Ordering
Add
SK
, angle required,
right
(R)
or left
(L)
, and
square cut
(SQ)
or bevel cut
(BV)
to product number.
Example: THF23118-2_SK45R_BV
100% of table load.
75% of uplift load on
skews greater than 15˚.
Add
SL,
slope required,
and up
(U)
or down
(D),
to product number.
Example: THF23118-2_SL30D
See Sloped Seat and Skewed
Example:
THF23118-2_SK45R_BV_SL30D
Add
IF,
to product number.
Example: THF23118-2_IF
1˚ to 50˚
100% of table load
Not available in
widths less than 2-1/4"
1˚ to 45˚
100% of table load.
65% of table load when
nailing into the support
members end grain.
80% of table load.
75% of uplift load on
skews greater than 15˚.
See Sloped Seat and Skewed
Specialty Options Chart – refer to Specialty Options pages 320-321 for additional details.
Designed to provide lateral support for the top chords of I-Joists in
depths up to 16".
Materials: See EWP Face Mount Hangers charts, page 217
Finish: G90 galvanizing
Options: See Specialty Options chart
Codes: IBC, FL, LA
Installation:
Use all specied fasteners. See Product Notes, page 18.
• Web stiffeners are required for I-Joist installations.
Typical THF I-Joist to
I-Joist installation
Typical THF double I-Joist
to LVL installation
THF
H
W
2-1/2"
A