Use and Care Manual

EWP Hangers
225
MiTek
®
Product Catalog
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
EWP Hangers
Top Mount Hanger Charts
Fastener Schedule
5
Uplift
2
DF/SP
Ref. No. Ga W H D L TF Type Qty Type LVL PSL LSL SPF DF/SP
160%
TFI420
HIT420,
MIT420
-- 16 3-9/16 20 2-1/2 -- 2-1/8 4 2 16d 2 10d x 1-1/2 2715 2715 2715 2075 -- 2715 215
BPH3520 BA3.56/20 x 12 3-9/16 20 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3520 HB3.56/20 x 10 3-9/16 20 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3520 WP3.56 H=20 x 7/10 3-5/8 20 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3520
HWP3.56 H=20,
HWPH3.56 H=20
x 7 3-9/16 20 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
HLBH3520 HGLT4 H=20 x 7 3-5/8 20 6 12 3-1/8 3 12 NA16D-RS 6 16d 10045 10045 10045 7705 -- 10045 1420
TFI422 HIT422 -- 16 3-9/16 22 2-1/2 -- 2-1/8 4 6 16d 2 10d x 1-1/2 2820 2820 2820 2480 -- 2820 215
BPH3522 BA3.56/22 x 12 3-9/16 22 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3522 HB3.56/22 x 10 3-9/16 22 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3522 WP3.56 H=22 x 7/10 3-5/8 22 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3522
HWP3.56 H=22,
HWPH3.56 H=22
x 7 3-9/16 22 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
TFI424 HIT424 -- 16 3-9/16 24 2-1/2 -- 2-1/8 4 6 16d 2 10d x 1-1/2 2820 2820 2820 2480 -- 2820 215
BPH3524 BA3.56/24 x 12 3-9/16 24 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3524 HB3.56/24 x 10 3-9/16 24 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3524 WP3.56 H=24 x 7/10 3-5/8 24 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3524
HWP3.56 H=24,
HWPH3.56 H=24
x 7 3-9/16 24 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
TFI426 -- -- 16 3-9/16 26 2-1/2 -- 2-1/8 4 6 16d 2 10d x 1-1/2 2820 2820 2820 2480 -- 2820 215
BPH3526 BA3.56/26 x 12 3-9/16 26 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3526 HB3.56/26 x 10 3-9/16 26 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3526 WP3.56 H=26 x 7/10 3-5/8 26 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3526
HWP3.56 H=26,
HWPH3.56 H=26
x 7 3-9/16 26 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
BPH3528 BA3.56/28 x 12 3-9/16 28 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3528 HB3.56/28 x 10 3-9/16 28 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3528 WP3.56 H=28 x 7/10 3-5/8 28 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3528
HWP3.56 H=28,
HWPH3.56 H=28
x 7 3-9/16 28 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
BPH3530 BA3.56/30 x 12 3-9/16 30 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
HBPH3530 HB3.56/30 x 10 3-9/16 30 3-1/2 -- 3 6 16 16d 10 16d 6310 6310 6310 5035 -- 6310 2705
PHM3530 WP3.56 H=30 x 7/10 3-5/8 30 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3530
HWP3.56 H=30,
HWPH3.56 H=30
x 7 3-9/16 30 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
BPH3532 -- x 12 3-9/16 32 2-3/4 --
3
4 6 16d 6 10d 3050 3050 3050 2345 -- 3050 1140
PHM3532 -- x 7/10 3-5/8 32 2-1/2 7 3 2 -- 16d 2 10d 3335 3335 3335 2535 -- 3335 --
PHXU3532 -- x 7 3-9/16 32 3-1/4 10 2-1/2 4 4 16d 6 10d 5910 5910 5910
4535
-- 5910 1120
THO20950-2
MIT4.12/9.5,
BA4.12/9.5
x 16 4-3/16 9-1/2 3 -- 2 4 6 16d 6 10d 2920 2920 2920 2245 2630 2920 1135
PHM4295 WP4.12 H=9.5 x 7/10 4-3/16 9-1/2 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
THO20118-2
MIT4.12/11.88,
BA4.12/11.88
x 16 4-3/16 11-7/8 3 -- 2 4 6 16d 6 10d 2920 2920 2920 2245 2630 2920 1135
PHM42118 WP4.12 H=11.875 x 7/10 4-3/16 11-7/8 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
THO20140-2 BA4.12/14 x 12 4-3/16 14 3 -- 1-15/16 4 6 16d 6 10d 3640 3640 3640 2800 2630 3640 1145
PHM4214 WP4.12 H=14 x 7/10 4-3/16 14 2-1/2 7 3 2 -- 16d 2 10d 3265 3265 3265 2480 -- 3265 --
1) When I-joist is used as a header, all header nails must be 10d (0.148") x 1-1/2.
2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
3) Some listed loads may be increased for short-term loading. Refer to MiTek code evaluation reports for details.
4) When I-Joists with flanges less than 1-1/2" thick are used as headers, the reduction factor for 1-1/4" flange is 0.69 and 0.84 for 1-3/8" flange.
5) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long.
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.
New products or updated product information are designated in blue font.
Allowable Loads Header Type (Lbs.)
1,3
3-1/2 x 32
Header Joist Download 100%
DF
I-Joist
4
3-1/2 x 28
3-1/2 x 30
Dimensions (in)
MiTek USP
Stock No.
Web
Stiff
Reqd
Joist Size
(in)
3-1/2 x 22
3-1/2 x 20
Top
Qty
Face
Qty
Code
Ref.
4 - 4-3/16 x
14
3-1/2 x 26
3-1/2 x 24
4 - 4-3/16 x
11-7/8
4 - 4-3/16 x
9-1/2
IBC,
FL,
LA
H
W
L
TF
D
Continued on next page