Use and Care Manual

240
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Glulam Beam Connectors
Glulam Beam Connectors
MiTek
®
Product Catalog
KHC Hinge Connectors
Supports a glulam beam off of another glulam beam. Refer to
the Optional Horizontal Loading Chart for design variations.
Materials: See chart
Finish: Primer
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
To allow for wood shrinkage, position bolts in slots away
from the bearing seat.
For dapped beams, reduce the “H” dimension by the “PT
dimension for each dap.
Ref. No. Qty Qty F1 160%
* KHC HCA 8 2 3/4 -- -- --
* KHC2T -- 9 2 3/4 2 3/4 --
KHC2CT -- 12 2 3/4 2 3/4 9445
KHCCT HCCTA 12 2 3/4 3 3/4 14170
KHC4CT -- 12 2 3/4 4 3/4 18895
* KHC3 HC3A 8 3 3/4 -- -- --
* KHC3T -- 9 3 3/4 3 3/4 --
KHC2C3T -- 12 3 3/4 2 3/4 9445
KHCC3T -- 12 3 3/4 3 3/4 14170
KHC4C3T HC4C3TA 12 3 3/4 4 3/4 18895
1) Loads are based on a 5-1/8" width Douglas-Fir Larch beam.
2) All bolts are 3/4", and shall meet or exceed the specifications of ASTM A 307.
3) Minimum H may be less than H required for listed loads; in which case,
load reductions are required.
* When used with optional KHCST Seismic Strap, the minimum H is 12".
MiTek USP
Stock No.
Prefix
Rotation
Bolts
2
/Beam
Seismic
Bolts
2
Min.
H
3
(in)
DF/SP
Allowable
Loads (Lbs.)
1
Dia
(in)
Dia
(in)
Typical KHC installation KHC3
KHC3
side view
KHC3
top view
Optional Horizontal Loading Chart
KHC4CT KHCCT
KHC4C3T
KHC2C3T
KHC2T
KHC3KHCC3T
KHC2CT
KHC3T
KHC
Continued on next page
W
H
PD
PT
3"
KHCST strap
Pg 241
F1
Rotation
tabs
Seismic