Use and Care Manual

Fasteners
27
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Fasteners
MiTek
®
Product Catalog
WSWH Washer Head Interior Structural Wood Screw Application
* T30 is a trademark of Acument
1.50" minimum
to loaded edge
1.50" minimum
to loaded edge
1.50" minimum
to loaded edge
0.75" minimum
to unloaded edge
0.75" minimum
to unloaded edge
0.75" minimum
to unloaded edge
2x10 Detail
2x12 Detail
2x6 Detail
0.75" minimum
to unloaded edge
2x8 Detail
1.50" minimum
to loaded edge
2x6 2 520 455
2x8 or 2x10 3 860 750
2x12 4 1040 900
1) Zinc = Yellow Zinc Dichromate; EXT = Exterior Coat.
2) Allowable loads are based on DF or equivalent wood members with a specific gravity ≥ 0.50,
or SPF/HF members with specific gravity in the following range: 0.42
<
SG < 0.50.
3) Gypsum board must be attached per building code requirements.
4) Screws must be installed in the center of the 2x stud, with a tolerance of 3/16" to
either side. Minimum loaded end distance for the stud is 3" and 6" when loaded away
from the end. Ledger end distance must be 6" or greater for full values. For ledger end
distances between 2" and 6" use 50% of the load table, for end distance between
2" and 4" predrill with a 5/32" bit.
5) The values above can be used when designing a ledger connection with (1) or (2)
layers of 5/8" gypsum board, a direct connection with no gypsum between the ledger
and studs, or a ledger connection with a single layer of APA rated 1/2" OSB.
6) Allowable loads are shown above at a load duration factor of C
D
= 1.00. Loads
may be increased where applicable to the current NDS. When in-service moisture
content is greater than 19%, use C
M
= 0.70.
7) For LRFD values, the values above should be adjusted in accordance with the
2018 NDS, Section 11.3.
8) Main members (stud) shall be loaded parallel to grain with a minimum penetration
of 2-1/4" while side members (ledger) shall be loaded perpendicular to grain with
a minimum penetration of 1-1/2".
WSWH45
WSWH5
EXT
Finish
1
WSWH45-EXT
WSWH5-EXT
MiTek Stock No.
Allowable Shear Per Stud (Lbs.)
2,5,6,7
DF/SP
SG ≥ 0.50
S-P-F/HF
0.42 ≤ SG < 0.50
Ledger
Size
9
Number
of Screws
per Stud
4,8
Zinc
Finish
1
Attaching 2x Ledger-to-Wall Studs Application
MiTek’s WSWH Washer Head Structural Wood Screw can be used to attach a ledger to studs
directly, through 1/2" APA rated sheathing or through one or two layers of 5/8" gypsum
wallboard (drywall). Screws are to be installed into the wide face of the single 2x
ledger, through the gypsum board and into the center of the narrow face of the 2x stud.
Installation:
Ledger design to be performed by a certied design professional.
• Locate studs in wall where ledger is to be installed.
Install MiTek’s WSWH5 structural wood screws through ledger and 5/8" gypsum
wallboard into wall framing using a T30* drive.
Follow the minimum edge distance guidelines in images shown below.
Wall design must be performed by certied design professional.
Care should be taken to install the ledger only where studs are plumb
and free of any defects.
WSWH45 should be used when no gypsum wallboard is present.
Typical 2x8 Ledger attached through
2 layers of 5/8" Gypsum Wallboard installation
Stud Wall
2 Layers of
5/8" Gypsum
Wallboard
WSWH5
Screws
3 per stud
2x8 Ledger
WSWH5
(Yellow Zinc nish)
WSWH45
(Exterior Coat nish)
5"
4-1/2"