Use and Care Manual

Truss & Rafter
263
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Truss & Rafter
MiTek
®
Product Catalog
HC / HCPRS / HHCP / LFTA / RT / TSP Hurricane Ties
Ref. No. Qty Type Qty Type Qty Type
4 8d x 1-1/2 4 8d -- -- 350 190 65 130 90 310 155 65 130 90
4 8d x 1-1/2 4 8d x 1-1/2 -- -- 345 190 65 130 90 305 155 65 130 90
RT4 -- 18 4 8d x 1-1/2 4 8d -- -- 305 205 140 230 230 270 165 140 190 160
RT5 -- 18 4 8d x 1-1/2 4 8d -- -- 380 160 80 280 180 335 160 80 225 180
RT6 HS24 18 8 8d x 1-1/2 6 8d -- -- 605 835 800 -- -- 535 670 575 -- --
5 8d x 1-1/2 5 8d -- -- 540 270 120 185 140 475 260 120 185 140
5 8d x 1-1/2 5 8d x 1-1/2 -- -- 515 270 120 185 140 455 260 120 185 140
5 8d x 1-1/2 5 8d -- -- 580 285 190 135 120 510 230 190 110 120
5 8d x 1-1/2 5 8d x 1-1/2 -- -- 630 285 190 135 120 510 230 190 110 120
RT7AT H2.5T 18 5 8d x 1-1/2 5 8d x 1-1/2 -- -- 480 250 150 240 165 425 200 145 240 165
RT8A H8 18 5 10d x 1-1/2 5 10d x 1-1/2 -- -- 750 265 100 225 150 660 265 100 225 150
6 8d x 1-1/2 8 8d 6 8d 540 270 120 185 140 475 260 120 185 140
6 8d x 1-1/2 6 8d x 1-1/2 6 8d x 1-1/2 515 270 120 185 140 460 270 120 185 140
5 8d x 1-1/2 5 8d -- -- 500 490 220 415 -- 440 395 220 415 --
5 8d x 1-1/2 5 8d x 1-1/2 -- -- 580 490 220 415 -- 440 395 220 415 --
9 10d x 1-1/2 8 10d -- -- 1025 805 490 455 -- 900 660 345 455 --
9 8d x 1-1/2 8 8d x 1-1/2 -- -- 935 805 490 455 -- 820 660 345 455 --
RT16AR H10AR 18 9 10d x 1-1/2 8 10d -- -- 1025 805 490 455 -- 900 660 345 455 --
RT16-2 H10A-2 18 8 8d 8 8d -- -- 1060 780 410 405 -- 935 625 330 320 --
HHCP2 HCP2 18 10 10d x 1-1/2 10 10d x 1-1/2 -- -- 680 405 -- -- -- 595 355 -- -- --
HHCP4-TZ HCP4Z 16 8 10d 8 10d -- -- 1015 380 -- -- -- 885 330 -- -- --
-- -- 11 8d 6 8d 515 470 430 -- -- 445 405 370 -- --
-- -- 11 8d x 1-1/2 6 8d x 1-1/2 515 470 430 -- -- 445 405 370 -- --
HCPRS -- 18 6 8d 5 8d -- -- 490 525 345 570 -- 315 350 275 385 --
8 8d 8 8d -- -- 980 745 120 -- -- 825 625 100 -- --
8 8d x 1-1/2 8 8d x 1-1/2 -- -- 980 745 120 -- -- 825 625 100 -- --
RT20 H7 16 9 10d x 1-1/2 4 10d 9 10d x 1-1/2 1115 -- -- -- -- 980 -- -- -- --
3 10d x 1-1/2 3 10d x 1-1/2 -- -- 465 -- -- -- -- 390 -- -- -- --
9 10d x 1-1/2 6 10d x 1-1/2 -- -- 830 365 190 210 235 700 305 160 175 200
9 10d x 1-1/2 6 10d -- -- 870 365 190 210 235 730 305 160 175 200
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) LFTA6: To achieve F1 lateral loads, three nails must be installed on each side on the strap located closest to the bend line.
Lateral F1 and F2 load directions do not apply to roof truss-to-top plate installations.
3) 8d common nails may be substituted for 8d x 1-1/2 nails, and 10d common nails may be substituted for 10d x 1-1/2 nails.
4)
Stainless steel ring shank nails must be used with stainless steel connectors to achieve tabulated allowable loads.
5)
Non-identical hurricane ties are not to be combined to resist the uplift force or lateral loads at a single connection location.
6)
NAILS:
8d x 1-1/2 nails are 0.131" dia. x 1-1/2" long, 8d nails are 0.131" dia. x 2-1/2" long, 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in
blue font
.
IBC,
FL,
LA
--
IBC,
FL,
LA
GBC HC520 18
LFTA6
2
H6 16
18 H1
H2A 18
RT16A
H10A,
H14
18
MiTek
Stock No.
Steel
Gauge
RT3A
18-- RT7
RT7A H2.5A 18
H3 18
TSP TSP 16
Lateral
F3
160%
F4
160%
Lateral
F3
160%
F4
160%
F1
160%
F2
160%
Uplift
160%
Stud
RT15
RT10
Fastener Schedule
3,4,6
DF/SP Allowable Loads (Lbs.)
1
S-P-F Allowable Loads (Lbs.)
1
Code
Ref.
Corosion
Finish
F1
160%
F2
160%
Uplift
160%
Truss/Rafter Plate
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Materials: See chart
Finish: G90 galvanizing; HHCP4-TZ – G-185 galvanizing
Options: See chart for Corrosion Finish Options
Codes: See chart for code references
Installation:
• Use all specied fasteners. See Product Notes, page 18.
TSP Min Nailing – Fill all round holes.
TSP Max Nailing – Fill all round and diamond holes.
To achieve full allowable loads listed, fasteners must be installed as prescribed in the chart.
Depending on pitch, birdsmouth notching may be required with some models to enable installers to ll all nail holes.
• Designer shall determine if solid blocking is required.
LFTA6, RT4, RT5, and RT7 ship in equal quantities of left and right versions. Left version images shown.
Continued on next page
1) Allowable loads have been increased 60% for wind or seismic loads; no further
increase shall be permitted.
2) LFTA6: To achieve F1 lateral loads, three nails must be installed on each side on
the strap located closest to the bend line. Lateral F1 and F2 load directions do
not apply to roof truss-to-top plate installations.
3) 8d common nails may be substituted for 8d x 1-1/2 nails, and 10d common
nails may be substituted for 10d x 1-1/2 nails.
4) Stainless steel ring shank nails must be used with stainless steel connectors
to achieve tabulated allowable loads.
5) Non-identical hurricane ties are not to be combined to resist the uplift force
or lateral loads at a single connection location.
6) NAILS: 8d x 1-1/2 nails are 0.131" dia. x 1-1/2" long, 8d nails are 0.131" dia. x 2-1/2" long,
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in blue font.