Alternate Installations
Backer block installation
Wood blocking used to achieve full design load value of a face
mount hanger attached to a carrying member. Blocking to be
designed by truss designer or engineer of record.
• Wood blocking should be of similar size/grade as the truss
member to which it is attached. The blocking should be
designed to act as one unit with truss members.
• Truss designer shall approve blocking size/grade, fasteners
required, and application.
• All fasteners used to attach wood blocking should be
independent of the fasteners in the truss hanger.
Panel point installation
• Connection with face mount hanger attaching to a truss
panel point.
• Hanger nails that do not penetrate wood in panel point
provide no load resistance.
• Reduce load according to the code.
Filler block installation
Wood ller blocking used for supported member width less
than hanger width.
Blocking and blocking fasteners/quantity to be
designed by truss designer or engineer of record.