Use and Care Manual

325
Specialty Options
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Specialty Options
MiTek
®
Product Catalog
Welded Top Flange
• Weld sizes and lengths shown on chart.
Weld-on applications produce maximum allowable load
listed. Uplift loads do not apply to this application.
All welding should be done in accordance with the American
Welding Society (AWS) Standard by a certied welder.
Caution: Welding galvanized steel may produce
harmful fumes and should only be performed in
well-ventilated environments.
SW 3" 14 - 10 gauge 1/8"
7 gauge 3/16"
3 gauge 1/4"
HLBH, KHGLT 10"
Weld shall be distributed evenly.
Top Angle
Steel Gauge
Weld
Size
MiTek USP
Welded Hanger Series
Weld
Length
BPH, FWH, HBPH,
PHM, SWH
FWHBP, FWHFM, FWHH,
KLB, KHW, PHXU
KB, KGB, KHGB, KHHB,
KGLS, KGLST, KGLT,
KHGLS, KHGLST
4"
6"
8"
Typical top ange
welded installation
Typical top angle
welded installation
Continuous weld along
back of top ange
Part Number System
Part Numbers assigned to TFL, THO, IHFL, IHF, THFI and
THF I-Joist hangers reveal the I-Joist sizes to be used
with the specic hanger. This guide will teach you how
to recognize I-Joist dimensions in the part numbers.
1st, 3rd, and sometimes 4th digits are whole numbers
(This example denotes 2 and 11)
4th digit may be part of a decimal –
TFL 23118
2nd and 5th digits are decimals
(see guide below)
(This example denotes .3125
[5/16] and .875 [7/8])
5th digit may be (0) or dropped if height is even
THO 35 925 -2
Part Number Guide for Decimals
1 = .125 or 1/8 inch
2 or 25 = .25 or 1/4 inch
3 = .3125 or 5/16 inch
5 = .5 or 1/2 inch
6 = .625 or 5/8 inch
7 = .75 or 3/4 inch
8 = .875 or 7/8 inch
THO 3 5 925 -2
Letters
refer to
Hanger Series
ex.: THO
First (2) Digits
refer to
Member Width
ex.: 3.5 inches
Last (2) or
(3) Digits
refer to
Member Height
ex.: 9.25 inches
Digits after
Dash
refer to
Number of
Plies
ex.: 2-ply
Some Examples:
THO15950 .............. 1-1/2" x 9-1/2"
IHFL17925 ............... 1-3/4" x 9-1/4"
THO16925-2 ........... double 1-5/8" x 9-1/4"
THF23925-2............ double 2-5/16" x 9-1/4""
Note: MiTek’s USP Product Catalog lists a range of heights for IHFL/IHF
hangers. Face mount hangers can usually accommodate more than one I-Joist
height. The hanger height must be tall enough to support the top chord of the
I-Joist to eliminate web stiffener requirements for lateral stability. The IHFL/IHF
hanger must be a minimum of 60% of the joist height.
Top Angle Weld Length Chart
Typical
see chart