Concrete & Masonry
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Concrete & Masonry
MiTek
®
Product Catalog
Sill plate
Sill plate
Sill plate
Foundation wall
Foundation wall
Foundation wall
WS3 structural
wood screw
WS3 structural
wood screw
WS3 structural
wood screw
SRCP plate
SRCP plate
SRCP plate
½" 0/ Post-installed
concrete/masonry anchor
½" 0/ Post-installed
concrete/masonry anchor
½" 0/ Post-installed
concrete/masonry anchor
1/2" max
without shim
1/2" max
1-1/2" max
with shim
Typical SRCP installation
without shim, 1/2" max setback
SRCP Sill Retrofit Connector Plate
MiTek’s SRCP Sill Retrot Connector Plate is designed
as a retrot sill-to-foundation connection that can be
installed where there is minimal space between the
oor framing and top of the foundation wall. The
economical design is targeted for use in seismic
regions and yet is also suitable for use as a
supplementary connection in high wind areas.
The SRCP Sill Retrot Connector Plate can be installed
without shims anywhere the face of the sill plate is
within 1/2" of the face of the foundation wall.
Materials: 10 gauge
Finish: G90 galvanizing
Codes: See chart for code references
Installation:
For sill plate setbacks from 1/2" to 1-1/2", install
a wood shim (a minimum of 15" long) tight against
the sill plate and ush with the foundation wall.
See Figure 3.
Note: For any installations with a sill plate
setback, a shim plate is required to transfer
load in the F3 direction.
Install the ve MiTek WS3 structural wood screws
(included) in the slotted holes of the SCRP plate, thru
the shim (if applicable) and into the sill plate. MiTek’s
WS3 structural wood screws should be installed 3/4"
above the bottom of the sill plate (i.e. centered in the
narrow face for a 2x sill).
Drill and install two 1/2" diameter Power-Stud
®
anchors (or equivalent) into the foundation wall.
See manufacturer’s literature for proper installation
of post-installed anchors.
Ref. No. W H Qty Dia. Qty Type
Figure 1 1560 360 --
Figure 2 1560 -- 360
Figure 3
5
1560 360 360 IBC, FL, LA
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
MiTek's WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with each SRCP connector.
3
)
Use 1/2" diameter Power-Stud® anchors with minimum 3" embedment or e
q
uivalent.
4
)
Minimum concrete stren
g
th f'c = 2,500
p
si.
5
)
The shim must be fastened to the sill b
y
means other than MiTek's WS3 structural wood screws.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
6' 2 1/2 5 WS3 SRCP FRFP 10 11 6
DF/SP
Allowable Load (Lbs.)
1
Steel
Gauge
Maximum
Spacing to
Replace
1/2" or 5/8"
Anchor Bolt
Fastener Schedule
MiTek USP
Stock No.
Dimensions (in)
Concrete
3,4
Sill Plate
2
--
F1
160%
F2
160%
F3
160%
Installation
Type
Code
Ref.
Typical SRCP installation
without shim, 1/2" max overhang
Shim added between
SRCP Plate & Sill. The
shim must be fastened
to the sill by means other
than the WS structural
wood screws.
Typical SRCP installation
with shim, 1-1/2" max setback
11"
6"
SRCP
Figure 1
Figure 2
Figure 3
F1
F1
F2
F3
F1
F1
F2
F3
F1
F1
F2
F3