Use and Care Manual

61
Concrete & Masonry
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Concrete & Masonry
MiTek
®
Product Catalog
SFA / SFJA Foundation Anchors
SFA – Mudsill anchors for retrot applications. Features
a slotted bend line for easy adjustment when foundation
walls are slanted
SFJA – Ties oor joists directly to foundations with
bolt fastening
Materials: 12 gauge
Finish: G90 galvanizing
Installation:
• Use all specied fasteners. See Product Notes, page 18.
A design professional must specify anchor bolt
type, length, and embedment. Anchor bolts are
laterally loaded. Follow installation instructions
for epoxy adhesive.
F1 Uplift
Ref. No. Qty Dia. Qty Type Qty Dia. 160% 160%
SFJA FJA 12 1 5/8 -- -- 2 5/8 -- 1305
SFA8 -- 12 2 1/2 7 10d x 1-1/2 -- -- 875 --
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) All bolts shall meet or exceed the specifications of ASTM A 307.
3) Fasteners shall be installed to fully grouted and reinforced masonry units (CMU) type S or better mortar or
reinforced concrete (f'c = 2,500 psi at 28 days).
4)
NAILS:
10d x 1-1/2 nails are 0.148" diameter by 1-1/2" long.
MiTek USP
Stock No.
Steel
Gauge
Nails
4
Bolts
2
Framing
Anchor
Bolts
Fastener Schedule
Code
Ref.
--
DF/SP
Allowable Loads (Lbs.)
1
Typical SFA8 installation
SFA8
F1
Typical SFJA installation
Uplift
8"
6"
7"
SFJA
1-1/2"
1-1/2"
6-1/2"
6"
1/2"
max gap
distance
Typical RP6 installation
RP6
Uses heavy gauge HRPO steel and a large surface area
to distribute seismic forces on masonry exteriors.
Materials: 3/8" plate
Finish: Primer
Options: See Chart for Corrosion Finish Options
Installation:
• Install with a 3/4" diameter steel threaded rod.
Ref. No.
RP6 RP6 --
Code
Ref.
Corrosion
Finish
MiTek USP
Stock No.
RP Retro Plate
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
6"
3"
6"
3"
3/4" dia.
threaded rod