KLCC Lally Column Caps
Ref. No. W H L Qty Type
KLCC45-35 LCC4.5-3.5 12 4-5/8 4 11-1/2 Triple 2x10/12 8 16d 3-1/2 16000 16000 --
KLCC45-4 LCC4.5-4 12 4-5/8 4 11-1/2 Triple 2x10/12 8 16d 4 21000 21000 --
KLCC6-35 LCC6-3.5 12 6-1/8 4 11-1/2 Quad 2x10/12 8 16d 3-1/2 16000 16000 --
KLCC6-4 LCC6-4 12 6-1/8 4 11-1/2 Quad 2x10/12 8 16d 4 21000 21000 --
KLCC35-35 LCC3.5-3.5 12 3-5/8 4 11-1/2 3.5 LVL / PSL 8 16d 3-1/2 -- -- 16000
KLCC35-4 LCC3.5-4 12 3-5/8 4 11-1/2 3.5 LVL / PSL 8 16d 4 -- -- 21000
KLCC525-35 LCC5.25-3.5 12 5-3/8 4 11-1/2 5.25 LVL / PSL 8 16d 3-1/2 -- -- 16000
KLCC525-4 LCC5.25-4 12 5-3/8 4 11-1/2 5.25 LVL / PSL 8 16d 4 -- -- 21000
KLCC7-35 LCC7-3.5 12 7-1/8 4 11-1/2 7 LVL / PSL 8 16d 3-1/2 -- -- 16000
KLCC7-4 LCC7-4 12 7-1/8 4 11-1/2 7 LVL / PSL 8 16d 4 -- -- 21000
1) Loads may not be increased for short-term loading.
2) Loads are for a continuous beam.
3) Allowable loads are determined using the lowest of the bearing loads. Use Fc-perp equal to 425 psi for SPF, 625 psi for DF and 700 psi for LVL/PSL,
or the lally column capacity.
4) Spliced conditions must be detailed by the designer to transfer tension loads between spliced members by means other than the lally column.
The splice condition load is 6750 lbs. per beam side and the lally cap must be evenly loaded.
5)
NAILS:
16d nails are 0.162" dia. x 3-1/2" long.
--
Column
Outside
Dia. (in)
Fastener Schedule
Nails
5
Code
Ref.
LVL / PSL
Allowable
Loads (Lbs.)
1,2,3,4
MiTek USP
Stock No.
Steel
Gauge
DF/SP
Allowable
Loads (Lbs.)
1,2,3,4
S-P-F
Allowable
Loads (Lbs.)
1,2,3,4
Girder
Dimensions (in)
Lally Column Caps connect lally columns to wood beams.
Fits 3-1/2" and 4" diameter lally columns.
Materials: 12 gauge
Finish: Primer
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Fit KLCC onto lally column. Position wood beam in KLCC
saddle and fasten.
Typical KLCC installation
KLCC
H
W
L