Lumber Hangers
Lumber Hangers
MiTek
®
Product Catalog
Face Mount Hangers – DF/SP Allowable Loads
Floor
Uplift
1
Joist Size Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160%
JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 -- 8 16d 6 16d 1845 2105 2290 2345
10d 1750 1965
16d 2000 2000
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1950
Min 14 6 2155 2430 2610 1170
Max 20 10 3080 3475 3725 1950
HDQ210-3IF HUCQ210-3 14 4-5/8 9 3 1-1/2 -- 12 WS3 6 WS3 5015 5590 5590 2975
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 -- 8 16d 6 16d 1845 2105 2290 2345
10d 1750 1965
16d 2000 2000
HDQ210-3IF HUCQ210-3 14 4-5/8 9 3 1-1/2 -- 12 WS3 6 WS3 5015 5590 5590 2975
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
Min 18 8 2770 3125 3355 1510
Max 26 12 4005 4515 4845 2340
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
Min 16 8 2465 2780 2980 1305
Max 24 12 3695 4170 4470 2340
Min 18 8 2770 3125 3355 1510
Max 26 12 4005 4515 4845 2340
Min 22 10 3390 3820 4100 1950
Max 30 14 4620 5035 5035 2735
Min 10 4 1540 1735 1865 870
Max 14 6 2155 2430 2610 1305
Min 14 6 2155 2430 2610 1305
Max 18 8 2770 3125 3355 1845
Min 14 6 2155 2430 2610 1305
Max 18 8 2770 3125 3355 1845
Min 14 6 2155 2430 2610 1305
Max 18 8 2770 3125 3355 1845
JUS44 LUS44 18 3-5/8 3-1/4 2 1 -- 4 16d 2 16d 780 780 780 660
10d 750 840 910
16d 880 1000 1080
HD44 HU44 14 3-9/16 3-5/16 2-1/2 1-1/8 -- 4 16d 2 10d 615 695 745 390
HD44IF HUC44 14 3-9/16 3-5/16 2-1/2 -- -- 4 16d 2 10d 615 695 745 390
1
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
For JUS and HUS han
g
ers: Nails must be driven at a 30° to 45˚ an
g
le throu
g
h the
j
oist or truss into the header to achieve the table loads.
3
)
MiTek's WS3 structural wood screws are 1/4" dia. x 3" lon
g
and are included with HDQIF han
g
ers.
4
)
NAILS: 10d nails are 0.148" dia. x 3" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
2 10d6 380
6 10d14 11352000
113520006 10d14
10d
16d 10d
16d 10d
16d 10d
16d
16d
16d
4 x 4
--3-9/16 2-7/8 2 1-1/816 SUH44 U44
(4) 2 x 14 HD210-4 HU210-4 14 6-1/8 9-1/4 2-1/2 2 16d
(3) 2 x 16
HU210-4 14 6-1/8 9-1/4 2-1/2 2
HD216-3 HU216-3 14 4-5/8 13-1/4 2-1/2 1-1/8
16d
16d
(4) 2 x 10 HD210-4 HU210-4 14 6-1/8 9-1/4 2-1/2 2 16d
(4) 2 x 8 HD28-4 HU28-4 14 6-1/8 7 2-1/2 1-3/4 16d
(4) 2 x 12 HD210-4
16d
HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8 16d 10d
2-1/2 1-1/8 16d 10d
HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2
HD212-3 HU212-3 14 4-5/8 10-1/4
-- 16d 10d
HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2 -- 16d 10d
(3) 2 x 14
SUH210-3 U210-3 16 4-5/8 8-3/8 2 1
(3) 2 x 12
HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8
HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8
--
HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2 -- 10d
--
16d
HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 16d 10d
IBC,
FL,
LA
SUH210-3 U210-3 16 4-5/8 8-3/8 2 1 --
HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 16d 10d
HD210-3IF HUC210-3 14 4-5/8 8-1/4 2-1/2
MiTek USP
Stock No.
Steel
Gauge
Min/
Max
Roof
Code
Ref.
Dimensions (in)
Fastener Schedule
3,4
DF/SP
Allowable Loads (Lbs.)
2
Corrosion
Finish
Header Joist
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish
Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
A
D
H
W
Continued on next page