Use and Care Manual

170
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Lumber Hangers
Lumber Hangers
MiTek
®
Product Catalog
Top Mount Hanger Charts
Floor
Uplift
1
Ref. No. W H D L TF Top Face Type Qty Type 100% 115% 125% 160%
SWH210-2 WP210-2 7/12 3-1/8 9-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
HDO210-2
HU210-2TF,
HUS210-2TF
12 3-1/8 9-1/8 2-1/4 -- 2-1/2 4 10 16d 6 10d 4575 4575 4575 1275
HDO210-2IF
HUC210-2TF,
HUSC210-2TF
12 3-1/8 9-1/8 2-1/4 -- 2-1/2 4 10 16d 6 10d 4575 4575 4575 1275
SWH212-2 WP212-2 7/12 3-1/8 11-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
HDO212-2
HU212-2TF,
HUS212-2TF
12 3-1/8 11 2-1/2 -- 2-1/2 4 12 16d 6 10d 5155 5465 5675 1275
SWH214-2 WP214-2 7/12 3-1/8 13-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
HDO214-2
HU214-2TF,
HUS214-2TF
12 3-1/8 13 2-1/2 -- 2-1/2 4 14 16d 8 10d 5500 5845 6080 1510
SWH216-2 WP216-2 7/12 3-1/8 15-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
HDO216-2 HU216-2TF 12 3-1/8 15 2-1/2 -- 2-1/2 4 16 16d 8 10d 5845 6010 6100 1700
4 x 4 HDO44 HU44TF 12 3-9/16 3-7/16 2-1/4 -- 2-1/2 4 4 16d 2 10d 2965 2965 2965 400
SW46 WP46 12 3-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- 10d 2 10d 2520 2520 2520 135
HDO46 HU46TF 12 3-9/16 5-3/8 2-1/4 -- 2-1/2 4 6 16d 4 10d 4125 4320 4450 825
KHW46 -- 3/10 3-9/16 5-3/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
SW48 WP48 12 3-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- 10d 2 10d 2520 2520 2520 135
HDO48
BA48,
HU48TF
12 3-9/16 7-1/8 2-1/4 -- 2-1/2 4 8 16d 4 10d 4465 4575 4575 825
KHW48 -- 3/10 3-9/16 7-1/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
SW410 -- 12 3-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- 10d 2 10d 2520 2520 2520 135
HDO410
BA410,
HU410TF
12 3-9/16 9-1/8 2-1/4 -- 2-1/2 4 10 16d 6 10d 4785 4785 4785 1275
SWH410 WP410 7/12 3-9/16 9-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
KHW410 -- 3/10 3-9/16 9-1/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
KB412 -- 12 3-9/16 11-1/8 2-3/8 -- 2-1/2 4 2 NA20D 2 NA20D 4075 4155 4185 580
HDO412 HU412TF 12 3-9/16 11 2-1/4 -- 2-1/2 4 12 16d 6 10d 5155 5465 5675 1275
SWH412 WP412 7/12 3-9/16 11-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
KHW412 -- 3/10 3-9/16 11-1/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
HDO414 HU414TF 12 3-9/16 13 2-1/2 -- 2-1/2 4 14 16d 8 10d 5500 5845 6080 1510
SWH414 WP414 7/12 3-9/16 13-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
KHW414 -- 3/10 3-9/16 13-1/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
HDO416 HU416TF 12 3-9/16 15 2-1/2 -- 2-1/2 4 16 16d 8 10d 5845 6230 6460 1700
SWH416 WP416 7/12 3-9/16 15-1/8 2-1/2 7 2-1/2 2 -- 16d 2 10d 3305 3305 3305 135
KHW416 -- 3/10 3-9/16 15-1/8 2-1/2 10 2-1/2 4 -- NA20D 2 10d 5535 5535 5535 135
1) Uplift Loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) KHW Glulam load values are based on 560 psi perpendicular to grain loading.
3) Refer to the respective Nailer Options chart on page 168 for hangers installed on wood nailers.
4)
NAILS:
10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long, NA20D nails are 0.192" dia. x 2-1/2" long
and are included with KB and KHW hangers.
(2) 2 x 10
Dimensions (in)
Fastener Schedule
4
DF/SP
Allowable Loads (Lbs.)
2,3
Header Joist
4 x 6
IBC,
FL,
LA
Beam/
Joist Size
MiTek
Stock No.
Steel
Gauge
Qty Roof
Code
Ref.
4 x 8
4 x 10
4 x 12
4 x 14
4 x 16
(2) 2 x 14
(2) 2 x 16
(2) 2 x 12
Continued on next page
D
H
W
L
TF