FHD Panel Hangers
The FHD26 hanger straddles the header and receives a joist from both sides.
Materials: 18 gauge
Finish: G90 galvanizing
Installation:
• Use all specied fasteners. See Product Notes, page 18.
In panelized construction, installers are allowed to nail through both the
sheathing and the hanger top ange with (1) 10d nail. The nail should be
centered in the top ange and be no closer than 1/4" from the back or front
edge of the top ange.
Typical FHD26
installation
FHD26
Ref. No. W H D Qty Type Qty Type Qty Type 125%
2 x 6 FHD26 PFDS26 18 1-9/16 5-3/8 1-1/2 2 16d 2 16d 2 10d x 1-1/2 960 175 --
1) Loads listed are per side.
2) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
3)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 16d nails are 0.162" dia. x 3-1/2" long.
10d x 1-1/2 nails may be substituted for 16d header nails with a maximum load of 960 lbs.
Code
Ref.
Joist
Size
MiTek USP
Stock No.
Steel
Gauge
Joist
Uplift
2
160%
Fastener Schedule
3
Face
DF/SP
Allowable Loads (Lbs.)
1
Dimensions (in)
Top
Header
3-1/8"
3-3/4"
H
D
W
The CSH-TZ concealed stringer hanger provides a method of connecting
a stair stringer with a hidden hanger. The seat of the hanger is adjustable
to match the slope of the stair stringer.
The reversible design allows the connector to be used on the left, right,
or interior stringers. The CSH-TZ may be used with MiTek’s SCA Stair Angles
for a complete, easy-to-use stair framing solution.
Materials: 18 gauge
Finish: G-185 galvanizing
Codes: IBC, FL, LA
Patents: U.S. Patent No. 7,631,463
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Bend angle only once.
Steps:
1. Attach CSH-TZ to header with tabs positioned towards the inside of the
stringer member.
2. Adjust the seat of the CSH-TZ to match the slope of the stringer member.
Diamond shaped holes in the connector allow temporary installation of
wood screws to aid in installation of the CSH-TZ.
3. Install 10d (0.148") x 1-1/2" HDG nails into the stringer and rim/band joist.
Typical CSH-TZ
installation
CSH-TZ
CSH Concealed Stringer Hanger
Ref. No. Qty Type Type 100% 115% 125% 100% 115% 125%
CSH-TZ LSCZ 18 8 10d x 1-1/2 HDG
41
10d x 1-1/2
HDG
890 890 890 370 725 725 725 305
IBC,
FL, LA
1) Uplift loads are increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
Stainless steel ring shank nails must be used with stainless steel connectors to achieve tabulated allowable loads.
3)
NAILS:
10d x 1-1/2 HDG nails are 0.148" dia. x 1-1/2" long.
New products or updated product information are designated in
blue font
.
Code
Ref.
MiTek USP
Stock No.
Steel
Gauge
Rim/Band Joist
DF/SP
Allowable Loads (Lbs.)
S-P-F/Hem Fir
Allowable Loads (Lbs.)
Corrosion
Finish
Uplift
160%
Uplift
160%
Stringer
Wide
Face Qty
Narrow
Face Qty
Fastener Schedule
2,3
Adjustable
5"
5"
1-7/16"
1-1/2"
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc