HWUH Heavy-Duty Welded Universal Hangers
Floor
Uplift
1
W H Qty Type Qty Type 100% 115% 125% 160%
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 3925 4020 4085 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 10d 4615 4615 4615 955
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
NAILS:
10d nails are 0.148" dia. x 3" long.
Floor
Uplift
1
W H Qty Type Qty Type 100% 115% 125% 160%
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
Wood 6 NA21 5265 5265 5265 675
Masonry 2 1/2" x 6" J-Bolt 3060 3060 3060 1030
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
NAILS:
NA21 nails are 0.192" dia. x 1-3/4" long and are included with 4x, 6x, and 8x HWUH hangers.
--
--
Dimensions
(in)
Fastener Schedule
2
Supporting Member
Supported
Member
Wood Roof
Code
Ref.
DF/SP
Allowable Loads (Lbs.)
Installation
Type
7-1/2
7-1/2
7-1/2
7-1/2
11
13
16
11
13
16
5-3/8
7-1/8
9-1/8
5-1/2
5-1/2
5-1/2
7-1/2
7-1/2
5-1/2 5-3/8
5-1/2 7-1/8
5-1/2 9-1/8
11
13
16
3-1/8
3-1/8
3-1/8
3-1/8
3-9/16
5-3/8
7-1/8
9-1/8
11
13
16
3-9/16
3-9/16
3-9/16
3-9/16
3-9/16
5-3/8
7-1/8
9-1/8
11
13
16
11
7-1/8
9-1/8
13
16
5-3/8
HWUH816
1-5/8 5-3/8
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
2-5/8
2-5/8
2-5/8
2-5/8
2-5/8
2-5/8
3-1/8
3-1/8
HWUH86
HWUH88
HWUH810
HWUH812
HWUH814
HWUH68
HWUH610
HWUH612
HWUH614
HWUH616
HWUH410
HWUH412
HWUH414
HWUH416
HWUH66
HWUH212-2
HWUH214-2
HWUH216-2
HWUH46
HWUH48
MiTek USP
Stock No.
8 x 16
HWUH26
HWUH28
HWUH210
HWUH212
HWUH214
HWUH216
HWUH36
HWUH38
HWUH310
HWUH312
HWUH314
HWUH316
HWUH26-2
HWUH28-2
HWUH210-2
8 x 6
8 x 8
8 x 10
8 x 12
8 x 14
6 x 8
6 x 10
6 x 12
6 x 14
6 x 16
4 x 10
4 x 12
4 x 14
4 x 16
6 x 6
(2) 2 x 12
(2) 2 x 14
(2) 2 x 16
4 x 6
4 x 8
Beam/
Joist Size
--
2 x 4 - 6
2 x 8
2 x 10
2 x 12
2 x 14
2 x 16
3 x 6
3 x 8
3 x 10
3 x 12
3 x 14
3 x 16
(2) 2 x 6
(2) 2 x 8
(2) 2 x 10
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Ref. No.
--
--
--
--
--
--
--
--
--
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
10d
4 10d
4 10d
4 10d
4 10d
4 10d
4
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
4 10d
10d x 1-1/2
4 10d x 1-1/2
4 10d x 1-1/2
Beam/
Joist Size
MiTek USP
Stock No.
Wood Roof
4 10d x 1-1/2
4 10d x 1-1/2
4
--
--
--
--
--
7-1/8
9-1/8
Code
Ref.
Supported
Member
DF/SP
Allowable Loads (Lbs.)
Installation
TypeRef. No.
Dimensions
(in)
Supporting Member
Fastener Schedule
2
4 10d x 1-1/2
--
Versatile heavy-duty top ange hanger attaches to both wood and
masonry. Unique design allows builders to use one style hanger on
the job when the structure has a variety of support materials.
Materials: Top Flange – 3 gauge; Stirrup – 7 gauge
Finish: Primer
Options: See Specialty Options Chart on page 191
Installation:
• Use all specied fasteners. See Product Notes, page 18.
• NA21 nails are included with hangers where specied.
NA21 nails are not recommended for use with LVL, PSL,
or LSL headers.
Masonry design load values apply to both solid concrete tie beams
and grout-lled CMU walls.
Alternate installation – Use (2) 1/2" x 4" DeWalt Screw-Bolt+
TM
or equal for loads up to 2,400 lbs. when attaching to CMU.
Loads shall not exceed table loads.
Typical HWUH410
wood-to-masonry installation
HWUH
Typical HWUH410
wood-to-wood installation
H
W
3-1/2"
3-1/2"
3-1/2"
10"