EWP Hangers
LSSH Slope/Skew Hangers
The LSSH series connects rafters to ridge beams in vaulted roof
structures. This series is eld adjustable to meet a variety of skew
and/or slope applications. Slopes and skews 0° to 45°.
Materials: See chart
Finish: G-185 galvanizing
Options: See chart for Corrosion Finish Options
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Steps:
1. Position LSSH connector against plumb-cut end of joist. Fasten
joist side anges on both sides with 10d (0.148") x 1-1/2" HDG
nails. Bend seat up to t against joist bottom and drive
(1) 10d (0.148") x 1-1/2" HDG nail through bottom seat into
rafter bottom. Drive (2) 10d (0.148") x 1-1/2" HDG nails at
downward angle through dimpled nailing guides.
2. Lean connector and rafter end against ridge beam at desired
position. Install specied 10d (0.148" x 3") HDG or
16d (0.162" x 3-1/2") HDG nails through nail holes into ridge
beam at right 90° angle. If skewing the rafter, only drive nails
into ridge beam on inside ange.
3. Bend ange to desired angle.
4. Hammer outside ange until edge touches header. Fasten outside
ange to ridge by driving specied 10d (0.148" x 3) HDG or
16d (0.162" x 3-1/2") HDG nails through nail holes.
• Web stiffeners are required for all wood I-Joist installations.
Designer may consider adding a tension restraint for the supported
member for roof slopes exceeding 6/12. Refer to page 122.
Floor
Uplift
1
Floor
Uplift
1
Ref. No. W1 W2 Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
1-1/2 LSSH15-TZ
LSSJ26LZ, LSSJ26RZ,
LSSJ28LZ, LSSJ28RZ
18 1-9/16 1-3/4 6 10d HDG 7 10d x 1-1/2 HDG 720 820 885 565 640 730 785 440
1-1/2 LSSH210-TZ LSSJ210LZ, LSSJ210RZ 18 1-9/16 1-3/4 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 410 1065 1090 1090 320
1-3/4 LSSH179-TZ LSSR1.81Z 18 1-13/16 1-5/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
2 - 2-1/8 LSSH20-TZ LSSR2.1Z 18 2-1/8 2-1/2 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 795 1065 1085 1085 620
2-1/4 - 2-5/16 LSSH23-TZ LSSR2.37Z 18 2-5/16 2-3/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 795 1065 1085 1085 620
2-1/2 LSSH25-TZ LSSR2.56Z 16 2-9/16 2-3/4 18 16d HDG 12 10d x 1-1/2 HDG 2095 2095 2095 945 1640 1640 1640 740
2-5/8 LSSH26-TZ -- 16 2-11/16 2-5/8 18 16d HDG 12 10d x 1-1/2 HDG 2095 2095 2095 945 1640 1640 1640 740
3 LSSH31-TZ LSSR210-2Z 16 3-1/8 3-3/4 18 16d HDG 12 10d x 1-1/2 HDG 2645 3000 3090 1310 2345 2415 2415 1025
3-1/2 LSSH35-TZ LSSR410Z 16 3-9/16 3-1/2 18 16d HDG 12 10d x 1-1/2 HDG 2645 3000 3090 1310 2345 2405 2405 1020
1-1/2 LSSH15-TZ
LSSJ26LZ, LSSJ26RZ,
LSSJ28LZ, LSSJ28RZ
18 1-9/16 1-3/4 6 10d HDG 7 10d x 1-1/2 HDG 620 620 620 510 485 485 485 400
1-1/2 LSSH210-TZ LSSJ210LZ, LSSJ210RZ 18 1-9/16 1-3/4 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
1-3/4 LSSH179-TZ LSSR1.81Z 18 1-13/16 1-5/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1370 1395 880 1065 1090 1090 690
2 - 2-1/8 LSSH20-TZ LSSR2.1Z 18 2-1/8 2-1/2 10 10d HDG 7 10d x 1-1/2 HDG 1200 1230 1230 795 960 960 960 620
2-1/4 - 2-5/16 LSSH23-TZ LSSR2.37Z 18 2-5/16 2-3/8 10 10d HDG 7 10d x 1-1/2 HDG 1200 1230 1230 795 955 955 955 620
2-1/2 LSSH25-TZ LSSR2.56Z 16 2-9/16 2-3/4 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 945 1260 1260 1260 740
2-5/8 LSSH26-TZ -- 16 2-11/16 2-5/8 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 945 1260 1260 1260 740
3 LSSH31-TZ LSSR210-2Z 16 3-1/8 3-3/4 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 1310 1260 1260 1260 1025
3-1/2 LSSH35-TZ LSSR410Z 16 3-9/16 3-1/2 14 16d HDG 12 10d x 1-1/2 HDG 1610 1610 1610 1310 1255 1255 1255 1020
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted
.
2) Stainless steel ring shank nails must be used with stainless steel connectors to achieve tabulated allowable loads
.
3) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d nails are 0.162" dia. x 3-1/2" long.
IBC,
FL,
LA
IBC,
FL,
LA
Rafter
Width (in)
Dimensions
(in)
Code
Ref.
SLOPED ONLY HANGER
S
SKEWED HANGERS or SLOPED & SKEWED HANGERS
MiTek
Stock No.
Steel
Gauge
Roof Roof
Corrosion
Finish
Fastener Schedule
2,3
Header Rafter
DF/SP
Allowable Loads (Lbs.)
S-P-F
Allowable Loads (Lbs.)
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Typical LSSH179-TZ
installation
LSSH35-TZ
Skew to 45° maximum
2
3 & 4
1
LSSH15-TZ = 5-1/16"
All other sizes = 8-7/8"
W2 W1 W2
3"
Slope to 45° up
or down
LSSH210-TZ
W2
W1
W2
3"
Slope to 45°
up or down
8-7/8"