Use and Care Manual

271
Plated Truss
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Plated Truss
MiTek
®
Product Catalog
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Option
Skewed
1,3
Sloped Seat
2
Sloped / Skewed
1,2,3
Range
1˚ to 45˚ 1˚ to 45˚ See Sloped Seat and Skewed
1) Skewed THDH hangers with skews greater than 15° always have all joist nailing on one side of the outside flange.
2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.
3) Skewed hangers typically require a bevel cut however, a square cut option may be available as a custom when requested.
Inverted flange option is not available for THDH models.
85% of table allowable load
Allowable
Loads
85% of table allowable load.
50% of table uplift load.
52% of table allowable load.
50% of table uplift load.
Ordering
Add
SK
, angle required,
right
(R)
or left
(L)
, and
square cut
(SQ)
or bevel cut
(BV)
to product number.
Ex. THDH410_SK45R_BV
Add SL, slope required,
and up (U) or down (D),
to product number.
Ex. THDH410_SL30D
See Sloped Seat and Skewed.
Ex. THDH410_SK45R_BV_SL30D
THDH Heavy-Duty Truss Hangers
Specialty Options Chart
– refer to Specialty Options pages 320-321 for additional details.
Floor
Uplift
1
Floor
Uplift
1
Ref. No. W H D A Qty Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
(3) 2 x 6 - 8 THDH26-3 HGUS26-3 5-1/8 5-7/16 4 2-1/2 20 16d 8 16d 4375 4895
5180 2805
3850
4105 4105 2220
(3) 2 x 8 - 10 THDH28-3 HGUS28-3 5-1/8 7-3/16 4 2-1/2 36 16d 12 16d 7595
8175 8175 4345 6500 6500 6500 3455
(3) 2 x 10 - 12 THDH210-3 HGUS210-3 5-1/8 9-3/16 4 2-1/2 46 16d 16 16d 9710 9710 9710
5290
7750 7750 7750
4225
(3) 2 x 12 - 14 THDH212-3 HGUS212-3 5-1/8 11-3/16 4 2-1/2 56 16d 20 16d
9530 9530 9530 5290 7635 7635 7635 4235
(3) 2 x 14 - 16 THDH214-3 HGUS214-3 5-1/8 13-3/16 4 2-1/2 66 16d 22 16d
11325 11325 11325 5305 9085 9085 9085 4255
6 x 10 - 12 THDH610
HGUS5.25/10,
HGUS5.50/10
5-1/2 9 4 2-1/2 46 16d 16 16d 9020 9020 9020
5290 7805 7805 7805 4210
6 x 12 - 14 THDH612
HGUS5.25/12,
HGUS5.50/12
5-1/2 11 4 2-1/2 56 16d 20 16d
9530 9530 9530 5290 7610 7610 7610 4225
6 x 14 - 16 THDH614 HGUS5.50/14 5-1/2 13 4 2-1/2 66 16d 22 16d
11325 11325 11325 5305 9055 9055 9055 4245
(4) 2 x 6 - 8 THDH26-4 HGUS26-4 6-9/16 5-7/16 4 2 20 16d 8 16d 4375 4895
5180 2805
3850
4095 4095 2215
(4) 2 x 8 - 10 THDH28-4 HGUS28-4 6-7/16 7-9/16 4 2-1/2 36 16d 12 16d 7595
8175 8175 4345 6480 6480 6480 3445
6-3/4 x 9 - 14 THDH6710
HGUS210-4,
HGUS6.88/10
6-7/8 8-13/16 4 2-1/2 46 16d 12 16d 9020 9020 9020
4345 7765 7765 7765 3445
6-3/4 x 11 - 18 THDH6712
HGUS212-4,
HGUS6.88/12
6-7/8 10-13/16 4 2-1/2 56 16d 14 16d 9020 9020 9020
5290 7775 7775 7775 4195
6-3/4 x 13 - 20 THDH6714
HGUS214-4,
HGUS6.88/14
6-7/8 12-13/16 4 2-1/2 66 16d 16 16d
11325 11325 11325 5305 8995 8995 8995 4215
7 x 9-1/4 - 14 THDH7210 HGUS7.25/10 7-1/4 9 4 2-1/2 46 16d 12 16d 9020 9020 9020
4345 7760 7760 7760 3440
7 x 11-1/4 - 16 THDH7212 HGUS7.25/12 7-1/4 10-1/2 4 2-1/2 56 16d 14 16d 9020 9020 9020
5290 7770 7770 7770 4195
7 x 14 - 20 THDH7214 HGUS7.25/14 7-1/4 12-1/4 4 2-1/2 66 16d 16 16d
11325 11325 11325 5305 8990 8990 8990 4215
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) Joist nails need to be toe nailed at a 30° to 45˚ angle to achieve allowable loads shown.
3)
NAILS:
16d nails are 0.162" dia. x 3-1/2" long.
New products or updated product information are designated in
blue font
.
Code
Ref.
IBC,
FL,
LA
Fastener Schedule
3
DF/SP
Allowable Loads (Lbs.)
S-P-F
Allowable Loads (Lbs.)
Corrosion
Finish
Header
Truss
2
Dimensions (in)
Joist /
Truss Size
MiTek USP
Stock No.
Roof Roof