Use and Care Manual

276
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Plated Truss
Plated Truss
MiTek
®
Product Catalog
MSHL/R Skewed Truss Hangers
The MSHL/R is a versatile 45° skewed hanger with multiple
installation options. It can be installed on a supporting girder truss
as well as solid-sawn and structural composite lumber headers.
Materials: See chart
Finish: G90 galvanizing
Codes: See chart for code references
Installation:
Install the required number of fasteners according to the load table.
Install fasteners into the carrying members at the locations
described below based on the proper “Mounting Condition.
Web stiffeners are required for I-Joist installations.
• Hanger is factory skewed at 45° left or right.
Typical MSH213R installation
Right skew
Typical MSH213L installation
Left skew
Uplift
1
Uplift
1
Ref. No. Type Qty Type 100% 115% 125% 160% 100% 115% 125% 160%
face-max -- 22 10d 6 10d x 1-1/2
1770 1770 1770 670 1430 1430 1430 540
top-max 4 6 10d 6 10d x 1-1/2
1810 1810 1810 670 1460 1460 1460 540
top-min 4 2 10d 6 10d x 1-1/2
1325 1325 1325
--
1240 1240 1240
--
combination 2 14 10d 6 10d x 1-1/2
1770 1770 1770 670 1430 1430 1430 540
face-max -- 14 10d 6 10d 1750
1755 1755 560 1395 1395 1395 445
top-max 4 6 10d 6 10d 1820 1820 1820
560 1490 1490 1490 445
top-min 4 2 10d 6 10d
1385 1385 1385
--
1100 1100 1100
--
combination 2 10 10d 6 10d 1750
1755 1755 560 1395 1395 1395 445
1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
NAILS:
10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in
blue font
.
Header
S-P-F
Allowable Loads (Lbs.)
Joist
Material
& Width
MiTek USP
Stock No. GA
Mounting
Condition
Joist
Fastener Schedule
2
DF/SP
Allowable Loads (Lbs.)
Top
Qty
Face
Qty
Download Download
3-1/2" LVL
or Floor
Trusses
Code
Ref.
THAL/R422 16
2x Lumber
or
Trusses
-- MSH213L/R
MSH422L/R
18
IBC,
FL,
LA
MSH213L
Left skew
13-1/4"
5"
1-5/8"
1-3/4"
Right skew Left skew
Drive nails
at angle
40° to 50°
Typical MSHL/R
face-max installation
Typical MSHL/R
top-max installation
Typical MSHL/R
top-min installation
Typical MSHL/R
combination installation
Install six (6) 10d x 1-1/2" nails into 2x carried member, or six (6) 10d nails into 3-1/2" wide carried member.
CONNECTION TO CARRYING MEMBER – Mounting Condition
CONNECTION TO CARRIED MEMBER – All Mounting Conditions
Top-Max
The straps must be eld-bent over
the header a minimum of 2" to
allow four (4) top ange nail holes
to be lled (two in each strap). The
bottom six (6) fastener holes (three
on each side of the bucket) must
be lled. Min. 2x6 bottom chord
required.
Top-Min
The straps must be eld bent over
the header a minimum of 2" to
allow four (4) top ange nail holes
to be lled (two in each strap). Also
install the two (2) uppermost face
nails (one on each strap) near the
top of the header.
MSH422R
Right skew
MSH422L
Left skew
22"
5-1/8"
1-3/4"
3-9/16"
9-5/16"
Combination
Face-Max/Top-Max
Follow the Face-Max installation
for one side of the connector
and
the Top-Max installation
for the
opposite side of the connector.
The Face-Max allowable loads
apply to this type of installation.
Min. 2x6 bottom chord required.
1) Uplift loads have been
increased 60% for wind
or seismic loads; no
further increase shall
be permitted.
2) NAILS: 10d x 1-1/2
nails are 0.148" dia. x
1-1/2" long, 10d nails
are 0.148" dia. x 3" long
New products or updated
product information are
designated in blue font.
Face-Max
For MSH422L/R, the bottom six (6)
fastener holes (three on each side of
the bucket) must be lled. Install eight
additional fasteners (four (4) in each
strap) where applicable. For MSH213L/R,
the bottom eight (8) fastener holes must
be lled (four (4) in each strap). Install
fourteen (14) additional fasteners, seven
(7) in each strap. Min. 2x6 bottom chord