Use and Care Manual

290
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Plated Truss
Plated Truss
MiTek
®
Product Catalog
SBP Supplementary Bearing Plates
100% 115% 125% 100% EBL 115% EBL 125% EBL
DF 625 2500 2805 2955 5780 6.17 6085 6.49 6235 6.65
SP 565 2745 2955 2955 5710 6.74 5920 6.99 5920 6.99
S-P-F 425 2200 2365 2365 4430 6.95 4595 7.21 4595 7.21
Hem Fir 405 2245 2445 2445 4370 7.19 4570 7.52 4570 7.52
DF 625 2500 2805 2955 9065 4.83 9370 5.00 9520 5.08
SP 565 2745 2955 2955 8680 5.12 8890 5.24 8890 5.24
S-P-F 425 2200 2365 2365 6665 5.23 6830 5.36 6830 5.36
Hem Fir 405 2245 2445 2445 6500 5.35 6700 5.51 6700 5.51
DF 625 2500 2805 2955 12345 4.39 12650 4.50 12800 4.55
SP 565 2745 2955 2955 11645 4.58 11855 4.66 11855 4.66
S-P-F 425 2200 2365 2365 8895 4.65 9060 4.74 9060 4.74
Hem Fir 405 2245 2445 2445 8625 4.73 8825 4.84 8825 4.84
DF 625 2500 2805 2955 15625 4.17 15930 4.25 16080 4.29
SP 565 2745 2955 2955 14610 4.31 14820 4.37 14820 4.37
S-P-F 425 2200 2365 2365 11125 4.36 11290 4.43 11290 4.43
Hem Fir 405 2245 2445 2445 10750 4.42 10950 4.51 10950 4.51
DF 625 3500 3930 4235 8655 9.23 9085 9.69 9390 10.02
SP 565 3845 4295 4295 8505 10.04 8955 10.57 8955 10.57
S-P-F 425 3080 3415 3415 6585 10.33 6920 10.85 6920 10.85
Hem Fir 405
3140 3525
3535 6480 10.67 6865 11.30 6875 11.32
DF 625 3500 3930 4235 13815 7.37 14245 7.60 14550 7.76
SP 565 3845 4295 4295 13170 7.77 13620 8.04 13620 8.04
S-P-F 425 3080 3415 3415 10095 7.92 10430 8.18 10430 8.18
Hem Fir 405 3140 3525 3535 9825 8.09 10210 8.40 10220 8.41
DF 625 3500 3930 4235 18970 6.74 19400 6.90 19705 7.01
SP 565 3845 4295 4295 17830 7.01 18280 7.19 18280 7.19
S-P-F 425 3080 3415 3415 13600 7.11 13935 7.29 13935 7.29
Hem Fir 405
3140 3525
3535 13165 7.22 13550 7.43 13560 7.44
DF 625 3500 3930 4235 24125 6.43 24555 6.55 24860 6.63
SP 565 3845 4295 4295 22490 6.63 22940 6.77 22940 6.77
S-P-F 425 3080 3415 3415 17105 6.71 17440 6.84 17440 6.84
Hem Fir 405 3140 3525 3535 16505 6.79 16890 6.95 16900 6.95
1) Allowable loads are for a pair of SBP devices. SBP's shall be installed in pairs.
2) Multiple ply trusses shall be fastened together to act as a single unit.
3) EBL denotes effective bearing length and includes the actual bearing length in inches plus
the contribution of the SBP device.
4) Assumes full seating of truss on top plate.
SBP6 on 2 x 6 Top Plate (5-1/2" wide)
4-Ply
1-Ply
2-Ply
3-Ply
4-Ply
1-Ply
2-Ply
3-Ply
SBP's Alone
SBP + Truss Bearing
4
Allowable Loads (Lbs.)
1,2,3
SBP4 on 2 x 4 Top Plate (3-1/2" wide)
No. of
Truss
Plies
Wood
Species
F
c
(psi)
W H Type Qty Type
2-7/8 or less 20 10d x 1-1/2
3 or more 20 10d
2-7/8 or less 28 10d x 1-1/2
3 or more 28 10d
1
)
Fastener Schedule is for a
p
air of SBP devices.
2
)
Allowable loads are for a
p
air of SBP devices. SBPs shall be installed in
p
airs.
3
)
Multi
p
le
p
l
y
trusses shall be fastened to
g
ether to act as a sin
g
le unit.
4
)
U
p
lift loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
5
)
Other connector models are not to be combined with SBP to resist the u
p
lift force or lateral loads.
For s
p
ecial considerations
,
consult MiTek Customer Service.
6
)
NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" lon
g,
10d nails are 0.148" dia. x 3" lon
g
.
New
p
roducts or u
p
dated
p
roduct information are desi
g
nated in blue font.
1195
Code
Ref.
IBC,
FL,
LA
1335820
820 1195 1335
5-1/2 3-1/4 1530 1625120510d84
S-P-F Allowable
Loads (Lbs.)
2,3
10d8
Truss
1530 16251205
F2
160%
Uplift
4
160%
F1
160%
F2
160%
Fastener Schedule
1,6
Plate
4
Top
Qty
Sides
Qty
Uplift
4
160%
Joist
Thickness
(in)
SBP6 TBE6
F1
160%
DF/SP Allowable
Loads (Lbs.)
2,3
Ref. No.
SBP4 TBE4 16 3-1/2 3-1/4
MiTek
Stock No.
Steel
Gauge
Dimensions
(in)
16
Use the SBP instead of extra truss plies or nail-on scabs to distribute concentrated truss reactions and avoid top plate
crushing. The two-piece design accommodates any number of girder plies. A wraparound design gives superior uplift
resistance, and reinforcement ribs effectively distribute bearing loads. Works with both single and double 2x4 or 2x6 top plates.
Materials: 16 gauge
Finish: G90 galvanizing
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
The SBP shall be installed in pairs.
Typical SBP
installation
SBP
H
W
2"
1"
1) Allowable loads are for a pair of SBP devices.
SBPs shall be installed in pairs.
2) Multiple ply trusses shall be fastened together
to act as a single unit.
3) EBL denotes effective bearing length in inches
and includes the actual bearing length plus the
contribution of the SBP device.
4) Assumes full seating of truss on top plate.
F1
F1
F2
F2
Uplift
1) Fastener Schedule is for a pair of SBP devices.
2) Allowable loads are for a pair of SBP devices. SBPs shall be installed in pairs.
3) Multiple ply trusses shall be fastened together to act as a single unit.
4) Uplift loads have been increased 60% for wind or seismic loads; no further
increase shall be permitted.
5) Other connector models are not to be combined with SBP to
resist the uplift force or lateral loads. For special considerations,
consult MiTek Customer Service.
6) NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long,
10d nails are 0.148" dia. x 3" long.
New products or updated product information are designated in blue font.