Use and Care Manual

310
Copyright © 2018 MiTek Industries, Inc. All Rights Reserved
General Hardware
General Hardware
MiTek
®
Product Catalog
ICPL / KNS / PL Protection Plates
Easy-to-install plates protect plumbing and power/communication
wiring from nail or screw penetration. 16 gauge steel conforms
to protection shield plate requirements of the National Electrical
Code and International Plumbing Code.
ICPL58 – Installs with nails.
KNS1 / PL4 – Prongs allow for quick installation.
Materials: 16 gauge
Finish: ICPL516-TZ – G-185 galvanizing;
All others – G90 galvanizing
Options: See chart for Corrosion Finish Options
Codes: IRC P2603.2.1 & R602.6.1, IBC 2308.5.8, IPC 305.6
Installation:
Use all specied fasteners. See Product Notes, page 18.
ICPL58
PL4
Typical ICPL58
installation
KNS1
ICPL516-TZ
Typical ICPL516-TZ
installation
Ref. No. W H Qty Type F1 160% F1 160%
ICPL58 -- 16 8-1/16 5 -- 4 8d or prongs -- --
PL4 NS2 16 2 5 -- -- prongs -- --
KNS1 NS1 16 1-1/2 3 -- -- prongs -- --
Sill Plate 12 16d HDG + prongs 1355 1160
Double Top Plate 16 16d HDG + prongs 1805 1550
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2)
NAILS:
8d nails are 0.131" dia. x 2-1/2" long, 16d nails are 0.162" dia. x 3-1/2" long.
Code
Ref.
DF/SP
Allowable
Loads (Lbs.)
1
S-P-F
Allowable
Loads (Lbs.)
1
PC
Corrosion
Finish
16-1/4
Installation
Type
Dimensions (in)
Fastener Schedule
2
5
MiTek USP
Stock No.
Steel
Gauge
ICPL516-TZ PSPN516Z 16
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
Typical KNS1 / PL4
installation
W
H
W
H
W
H
W
H