Use and Care Manual

342
Manufactured Housing Connectors
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
MH Connectors
MiTek
®
Product Catalog
Catalog installation notes should be followed when installing pneumatic nail hangers using alternative nails. All fasteners should be
installed into nailing zones and maintain minimum 1" center-to-center spacing. Alternative nail quantity required for installation of
pneumatic nail hangers can be determined using the table below.
54
(
lbs
)
x 1.15 = 62.1
(
lbs
)
nail
nail
54
(
lbs
)
x 1.60 = 86.4
(
lbs
)
nail
nail
Alternative Nails for Installation of Pneumatic Hangers
14 18 20 14 18 20
0.099 x 1-1/2" 0.099 1-1/2 67 58 56 58 50 48
0.100 x 1-3/8" 0.100 1-3/8 68 60 57 59 51 49
0.105 x 1-1/2" 0.105 1-1/2 74 65 63 64 56 54
0.113 x 2-3/8" 0.113 2-3/8 83 75 72 72 64 62
0.131 x 1-1/2" 1-1/2
0.131 x 3" 3
0.148 x 1-1/2" 0.148 1-1/2 127 118 116 110 102 100
1) Nail allowable load values were calculated as specified by the 2018 NDS; Sections 11 & 12, and Appendix I and L.
2) The nail lateral loads are adjusted by the Penetration depth factors,
C
d
, based on the length of the nails and thickness of the
steel side members. However, this assumes sufficient wood thickness to receive the full length of the nail or at least ten times
the diameter of the nail, whichever is less.
3) Adjustment factors for duration of load, service conditions and installation shall be applied to the nail values in accordance
with the provisions of the NDS delineated in Sections 2, 11 and 12.
4) The allowable load for any connector shall not exceed the catalog value
.
5) Fastener bending yield strength based on ASTM F1667-05 Table S1.1.
6) Quantity of fasteners must be used symmetrically in header flanges and into each side of joist.
7) Installation guidelines in MiTek's Product Catalog regarding pneumatic nail hangers must be followed.
S-P-F Allowable Shear per Nail (Lbs.)
1,2,3,4,5
Steel Gauge Steel Gauge
Fastener Description
Diameter Length
Dimensions (in)
DF/SP Allowable Shear per Nail (Lbs.)
1,2,3,4,5
85 830.131 107 98 96 92
Example:
JN28E (20 gauge) using .105 x 1-1/2" fasteners Header material: S-P-F
JN28E downward load at 115% = 1055 lbs. Joist material: S-P-F
JN28E uplift load at 160% = 245 lbs.
Nail Quantity Required for Downward Load:
Allowable shear capacity at 100% load duration = 54 lbs.
Use equal amount of fasteners in each side so use 9 nails in each ange for a total of 18.
Nail Quantity Required for Uplift:
Use equal amount of fasteners per side of joist so use 2 in each side for a total of 4.
Also make sure there are as many or more fasteners in the hanger to header connection.
18 nails in header ≥ 4 nails in joist.
Installation Notes
1055 lbs
= 17 nails
62.1
(
lbs
)
nail
245 lbs
= 3 nails
86.4
(
lbs
)
nail