HPA / PA / PAI Purlin Anchors
HPA series – For installation into poured concrete walls,
foundations, or masonry. The HPA is the heavy-duty version
of the PA anchor.
PA series – For installation into poured concrete or concrete
block walls and foundations.
PAI series – For wood I-Joist applications. An expanded 3"
on-center nail spacing reduces splitting along I-Joist ange.
Materials: HPA – 10 gauge; PA / PAI – 12 gauge
Finish: G90 galvanizing
Options: See chart for Corrosion Finish Options
Codes: IBC 1620.2.1
Installation:
• Use all specied fasteners. See Product Notes, page 18.
• Minimum concrete strength is 2,500 psi.
• The allowable loads for bolts are based on parallel to grain
loading with a 3" minimum member thickness, except the
HPA which requires a 3-1⁄2" thick wood member. Reduce
load per code requirements when minimum member
thickness is not achieved.
• Minimum concrete end/edge distance is 4" for PA / PAI series,
and 6" for HPA series.
• Minimum CMU end/edge distance is 20".
• Designer may specify alternate fastening schedules. Refer
to Nail Specication Table on page 23 for nail shear values.
Load values shall not exceed published allowable loads.
• No anchor bolts are needed for achieving efcient stress
transfer from framing to concrete walls or foundations.
Typical PA holdown
installation
Typical PA
purlin installation
Typical PAI
I-Joist purlin face installation
Ledger
#4 rebar
min
4"
PA / HPA
L
2-1/16"
1-1/2"
4-1/2"
PAI
L
2-1/16"
Continued on next page