Use and Care Manual

84
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Caps & Bases
Caps & Bases
MiTek
®
Product Catalog
RPB Retrofit Post Base
RPB-TZ post base attaches 4x4 or larger wood posts to
concrete or wood surfaces after the post is in place. Can be
installed with 1 or 2 RPB-TZs (single or double). Post may
also be installed on our CPB composite post base product
which provides a 1" stand off as required in untreated wood
installations. Installs with concrete screws, so no more
mis-installed, mis-located anchor bolts!
Materials: 12 gauge
Finish: G-185 galvanizing
Installation:
MiTek’s WS structural wood screws and screw
anchors are not included with RPB bases.
Not recommended for fence posts or other
unrestrained (not xed or fastened at top)
applications. These anchors are not designed
to resist overturning (moment) loads.
• Concrete Installation:
1. Place RPB-TZ over one corner of post ush
to both concrete and post surfaces and mark
hole locations in concrete. Place aside.
2. Drill holes for concrete screws using
appropriate bit and hammer drill.
3. Place RPB-TZ in position and install with
specied screw anchors as listed in table below.
4. Repeat for RPB-TZ on other side of post for
double installations.
• Wood-to-Wood Installation:
1. Place RPB-TZ over one corner of post ush
to wood base and post surfaces.
2. Install all specied MiTek WS structural wood
screws as listed in the table below.
3. Repeat for RPB-TZ on other side of post for
double installations.
Ref. No. Qty Wood Screw Qty Screw Anchor
2,3
2 3/8" x 2-1/2" 1525 710
4 Tapper+ 735 655
2 3/8" x 2-1/2" 1470 710
4 Tapper+ 735 655
2 3/8" x 2-1/2"
1470
9
710
4 Tapper+ 865 655
4 3/8" x 2-1/2" 2295
8 Tapper+ 1735
1 4 WS15 or WS3 4 1110
2 8 WS15 or WS3 8 2220
1) Allowable loads are for DF/SP 4x4, 6x6, or larger posts. For SPF/HF loads, multiply the allowable load by 0.86.
2
)
Use DeWalt 3/8" x 2-1/2" Screw-Bolt
TM
+ screw anchor
;
or e
q
ual
,
installed in accordance with
manufacturer's s
p
ecification. Screw anchors are not su
pp
lied.
3) Use Powers 1/4" x 1-3/4" Tapper+ concrete screw anchor (not supplied); or equal, installed in accordance with manufacturer's specification.
4) When installing connectors in pairs, the post must be a minimum of 2-1/2" from the edge of the concrete.
5) Allowable loads have been increased 60% for wind and seiesmic loads; no futher increase shall be permitted.
6) Concrete compressive strength shall be 2,500 psi or greater at 28 days.
7) LVL framing base shall be at least 1-3/4" thick.
8) SP framing base shall be at least 1-1/2" thick.
9) Allowable uplift for single RPB-TZ using WS3 structural wood screws with Screw-Bolt
TM
+ screw anchors for concrete base with post 2-1/2" from concrete edge is 1,525 lbs.
10) MiTek's structural wood screws and DeWalt screw anchors should be used only in interior-dry and non-corrosive environments.
11) Use MiTek's WS15-EXT or WS3-EXT structural wood screws when installing to treated wood.
495
495
495
495
990990
1 4 WS15
Post Base
RPB-TZ RPBZ 12
Uplift
160%
Concrete Base with Post 2-1/2" from Concrete Edge
4
MiTek USP
Stock No.
Steel
Gauge
1 4 WS15 or WS3
2
5
8 WS15 or WS3
WS15 960
F2
160%
Code
Ref.
--
Corrosion
Finish
LVL Base/SP Base
7,8
Concrete Base with Post Flush to Corner
6
1 4 WS3
DF/SP Allowable Loads (Lbs.)
1,5
Qty of
RPBs
Fastener Schedule
4
F3
160%
Typical double RPB-TZ
installation with CPB
composite post base
(CPB ordered separately)
Typical double RPB-TZ
wood-to wood
installation
Typical double RPB-TZ
concrete installation
Min 2-1/2" from any
concrete edge
(Top view)
Typical single RPB-TZ
installation at concrete
corner, ush to edge
(Top view)
RPB-TZ
1) Allowable loads are for DF/SP 4x4, 6x6, or larger posts. For SPF/HF loads, multiply the allowable
load by 0.86.
2) Use DeWalt 3/8" x 2-1/2" Screw-Bolt
TM
+ screw anchor; or equal, installed in accordance with
manufacturer's specication. Screw anchors are not supplied.
3) Use Powers 1/4" x 1-3/4" Tapper+ concrete screw anchor (not supplied); or equal, installed in
accordance with manufacturer's specication.
4) When installing connectors in pairs, the post must be a minimum of 2-1/2" from the edge
of the concrete.
5) Allowable loads have been increased 60% for wind and seismic loads; no further increase
shall be permitted.
6) Concrete compressive strength shall be 2,500 psi or greater at 28 days.
7) LVL framing base shall be at least 1-3/4" thick.
8) SP framing base shall be at least 1-1/2" thick.
9) Allowable uplift for single RPB-TZ using WS3 structural wood screws with Screw-Bolt
TM
+ screw
anchors for concrete base with post 2-1/2" from concrete edge is 1,525 lbs.
10) MiTek's structural wood screws and DeWalt screw anchors should be used only in interior-dry and
non-corrosive environments.
11) Use MiTek's WS15-EXT or WS3-EXT structural wood screws when installing to treated wood.
2-1/2"
2-1/4"
1-1/2"
5-1/8"
Typical double RPB-TZ
concrete installation
Uplift
RPB-TZ (2)
4x4
RPB-TZ
4x4
F3
F2
Corrosion Finish
Stainless Steel Gold Coat
HDG Triple Zinc
Corrosion Finish Stainless Steel Gold Coat HDG Triple Zinc
Corrosion
Finish
Stainless Steel
Gold Coat
HDG
Triple Zinc
1" gap
allowed
Smaller
fastener holes for
wood or concrete
installation
Larger fastener
hole for screw
anchor installation