Fire Wall Hangers
Fire Wall Hangers
MiTek
®
Product Catalog
FWHBP Fire Wall Hangers for Beams and Purlins
MiTek has expanded the FWH Fire Wall Hanger series to include the
higher load carrying capacity FWHBP, the Fire Wall Hanger for Beams
and Purlins. The FWHBP transfers the load into the supporting wall thru
bearing on the top plates and directly attaching to the stud pack or post
below. As with the FWH hanger, the advanced design allows you to
install the hangers before the drywall is attached, allowing your project
to be completely framed-up and weather-tight before the drywall
sheathing shows up on site.
Materials: 12 gauge
Finish: Primer
Options: See Specialty Options chart on page 197
Patents: U.S. Patent No. 10,179,992
Installation:
Install the face of hanger anges tight to stud wall framing.
The end of the truss/joist should measure 1-5/8" from the face of the
supporting wall.
The truss/joist should bear fully on the FWH seat with a gap no
greater than 1/8" between the end of the supported member and the
hanger.
Gypsum Wallboard Installation – Use the FWH-T template to slot
cut the gypsum wallboard. See FWH-T Template Sequence. Slide the
gypsum wallboard into position and fasten to the framing members
meeting the minimum requirements specied by code.
2x stud wall
framing
supported
beam
FWHBP hanger
stud pack
or post
2-layers
5/8" gypsum
board
2x stud wall
framing
supported
beam
FWHBP
hanger
stud pack
or post
2-layers
5/8"
gypsum
board
FWHBP Hanger FWHBP
Stud Pack Width
2-5/8"
H
2"
W1
A
W2
Typical FWHBP attachment to top plate/beam
and stud pack/post
Continued on next page
5-3/4"
FWH-T template
(must be ordered separately)
8"
13"
1) Align the FWH-Template slot
with the mark in the gypsum
wallboard and engage the
prongs into edge
of gypsum wallboard
FWH-T Template Installation Sequence
Edge prong
3) Run the gypsum
wallboard cutter
down the template
to cut the slot
2) Rotate the
template and
press down on
the end to engage
the corner prongs
Corner prong
FWH hangers are tested per ASTM E814 standards. When installed on one
side of a maximum 2 hour fire-rated wall assembly, the penetration of
the MiTek FWH Fire Wall Hanger through the gypsum wallboard will not
reduce the fire resistive rating of the 2 hour fire resistive assembly.
2 Hour Fire-Rating