Use and Care Manual

256
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Truss & Rafter
Truss & Rafter
MiTek
®
Product Catalog
RTM Hurricane Retrofit Connector
Designed as a retrot connector for trusses installed on top
plates. Can also be used as a holdown for a roof or oor system.
Materials: 18 gauge
Finish: G90 galvanizing
Codes: FL
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Concrete screws are not supplied with RT16M connector.
Install concrete screws in lower two holes for Single Top
Plate or Conventional Raised Foundation or Modular
Home Installations.
Moisture barrier may be required.
Typical RT16M
top plate installation
RT16M
Ref. No. Qty Type Qty Type Qty Screws (in)
-- -- 4 1395 630 125 490 1225 515 125 490
4 16d 2 1360 630 125 490 1200 515 85 400
1
)
Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be
p
ermitted.
2
)
Install with 1/4" x 1-3/4" Ta
p
con® Concrete Screws in accordance to manufacturer's installation s
p
ecifications.
3
)
Fasteners to be installed to full
y
g
routed and reinforced concrete masonr
y
.
4
)
Concrete com
p
ressive stren
g
th shall be 2,500
p
si or
g
reater at 28 da
y
s.
5
)
NAILS: 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" lon
g
, 16d nails are 0.162" dia. x 3-1/2" lon
g
.
New products or updated product information are designated in blue font.
HM9KT RT16M
Truss/Rafter
5
Top Plate
5
MiTek USP
Stock No.
18
Steel
Gauge
9 10d x 1-1/2
F3
160%
Fastener Schedule
Code
Ref.
FL
CMU/Concrete
2,3,4
Uplift
160%
DF/SP
Allowable Loads (Lbs.)
1
Uplift
160%
S-P-F
Allowable Loads (Lbs.)
1
1/4 x 1-3/4
Tapcon
F1
160%
F2
160%
F3
160%
F1
160%
F2
160%
Typical HGA10 installation HGA10
Designed for attaching gable end trusses to wood top plates and
masonry walls.
Versatile wood-to-wood connector that satises
high wind and seismic loading requirements.
Materials: 14 gauge
Finish: G90 galvanizing
Codes: IBC, FL, LA
Installation:
• Use all specied fasteners. See Product Notes, page 18.
Install with MiTek’s WS3 structural wood screws into top plate
and MiTek’s WS15 structural wood screws into the truss.
MiTek’s WS structural wood screws are included with HGA10 angles.
Moisture barrier may be required.
Ref. No. Qty Type Qty Type
2x4 340
250
2x6 1065
890
1) Allowable loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) MiTek's WS15 structural wood screws are 1/4" dia. x 1-1/2" long and WS3 structural wood screws are 1/4" dia. x 3" long.
3) The HGA10KT is a kit with (10) HGA10 angles packaged with MiTek's WS structural wood screws.
New products or updated product information are designated in
blue font
.
Code
Ref.
Uplift
160%
4 WS3
IBC,
FL, LA
790
1105 835
HGA10KT
3
HGA10KT 14 4 WS15
DF/SP Allowable Loads (Lbs.)
1
MiTek USP
Stock No.
Steel
Gauge
Fastener Schedule
2
Rafter/Truss Plate
F1
160%
F2
160%
F3
160%
Wall
Framing
S-P-F Allowable Loads (Lbs.)
1
Uplift
160%
F1
160%
F2
160%
515 820 620
F3
160%
HGA Hurricane Gusset Angles
5"
1-9/16"
8-15/16"
3-1/2"
3-1/2"
Embossed
gussets
improve
lateral load
resistance
3"
2"
F1
F1
F3
F2
Uplift
F1
F1
F3
F2
Uplift