Use and Care Manual

54
Copyright © 2020 MiTek Industries, Inc. All Rights Reserved
Concrete & Masonry
Concrete & Masonry
MiTek
®
Product Catalog
The FT form tie and WG wedge system allows concrete wall forms to be made from
2x nominal form lumber by accurately securing them in place while the concrete is
poured. This product is intended for a maximum wall height of 4 feet.
FT – Connect 1x and 2x nominal form lumber in low foundation walls up to 4 feet high
WG – V-shaped wedge assures rigidity and consistent form spacing
Materials: FT – 18 gauge, WG – 14 gauge
Finish: G90 galvanizing
Installation:
Use the Spacing Guide chart to determine spacing between FT units. Each
level in chart assumes 12" form boards. Wall thickness from 6" to 12".
• Install with “V” facing up.
Use (2) WG wedges for each tie. Insert wedge into inside slots
for 1x nominal forms and outside slots for 2x nominal forms.
• No walers or stiff-backs are used.
• Vertical ties to keep forms from separating are not included.
Form deection may be substantial. Check deection, if it is
critical, and move ties to compensate.
• Forming lumber is assumed to have fb of 1,000 psi.
Not recommended for pours greater than 4 feet in height.
Spacing Guide chart
Wedge
Ref. No.
W L Qty
FT6 WT6 18 5/8 10-5/8 2 6
FT8 WT8 18 5/8 12-5/8 2 8
FT10 WT10 18 5/8 14-5/8 2 10
FT12 WT12 18 5/8 16-5/8 2 12
WG W1 14 11/16 3-5/8 -- --
1) May be used with either 3/4" or 1-1/2" forming materials.
2) Breaking strength is approximately 775 pounds. Space as necessary to
prevent form blow-out.
1x 2x 1x 2x 1x 2x 1x 2x
12" or Less 2' 6" 4' 0" -- -- -- -- -- --
12" – 24" 1' 6" 3' 0" 2' 6" 4' 0" -- -- -- --
24" – 36" 1' 0" 2' 0" 1' 6" 3' 0" 2' 6" 4' 0" -- --
36" – 48" 0' 9" 1' 6" 1' 0" 2' 0" 1' 6" 3' 0" 2' 6" 4' 0"
1) Factor of safety against tensile failure of tie is 1.5 or more.
Level 1 Level 2 Level 3 Level 4
--
Footing Width
or Wall
Thickness
Concrete
Lift Height
Dimensions (in)
MiTek USP
Stock No.
Steel
Gauge
Code
Ref.
Wedge
Ref. No.
W L Qty
FT6 WT6 18 5/8 10-5/8 2 6
FT8 WT8 18 5/8 12-5/8 2 8
FT10 WT10 18 5/8 14-5/8 2 10
FT12 WT12 18 5/8 16-5/8 2 12
WG W1 14 11/16 3-5/8 -- --
1) May be used with either 3/4" or 1-1/2" forming materials.
2) Breaking strength is approximately 775 pounds. Space as necessary to
prevent form blow-out.
1x 2x 1x 2x 1x 2x 1x 2x
12" or Less 2' 6" 4' 0" -- -- -- -- -- --
12" – 24" 1' 6" 3' 0" 2' 6" 4' 0" -- -- -- --
24" – 36" 1' 0" 2' 0" 1' 6" 3' 0" 2' 6" 4' 0" -- --
36" – 48" 0' 9" 1' 6" 1' 0" 2' 0" 1' 6" 3' 0" 2' 6" 4' 0"
1) Factor of safety against tensile failure of tie is 1.5 or more.
Level 1 Level 2 Level 3 Level 4
--
Footing Width
or Wall
Thickness
Concrete
Lift Height
Dimensions (in)
MiTek USP
Stock No.
Steel
Gauge
Code
Ref.
WG Wedge
must order separately
FT
Typical FT/WG
installation
HN Hex Nuts
The HN nut is a standard hex nut manufactured from low carbon ASTM A563 Grade A steel (Proof Load = 90 ksi)
which makes it applicable for many common ASTM steel threaded rods of equivalent or lower strength.
Materials: ASTM A563 Grade A
Finish: See chart
Finish Ref. No. Finish Ref. No.
HN38 -- 0.375 HN38-ZP NUT3/8 0.375
HN12 -- 0.500 HN12-ZP NUT1/2 0.500
HN58 -- 0.625 HN58-ZP NUT5/8 0.625
HN34 -- 0.750 HN34-ZP NUT3/4 0.750
HN78 -- 0.875 HN78-ZP NUT7/8 0.875
HN1 -- 1.000 HN1-ZP NUT1 1.000
HN118 -- 1.125 HN118-ZP NUT1-1/8 1.125
None
Zinc
Plated
Dia.
(in)
Code
Ref.
MiTek USP
Stock No.
----
Code
Ref.
MiTek USP
Stock No.
Dia.
(in)
FT / WG Concrete Form Ties & Wedge
L
W
HN
11/16"
3-5/8"