User Manual

OpenMobility SIP Installation, Administration and Maintenance
Aastra DeTeWe Doc-ID: pm-0504 28.11.2006 Page: 33 (52)
3.3.3.3 User account
After initial installation or after removing the configuration file the
OpenMobility service is accessible via a build-in user account with user “
omm
and password “
omm
”. These settings which are case sensitive can be
changed on the “User Account” web page.
3.3.3.4 Time zones
A time and date resynchronization of the Aastra Phone 142 devices is
described in chapter 3.3.3.1.
In the time zone section the OpenMobility Manager provides all available
time zones. They are set with their known daylight savings time rules
adjusted to the Universal Coordinated Time (UTC) per default. The difference
to the UTC time is shown in the “UTC Difference” column. In case of a
configured daylight savings time rule this is also marked for each time zone.
There is a possibility to change the time zone rules for maximal five time
zones. Changed rules are marked with a bold time zone name in the table.
The changes are saved in the configuration file and are restored after each
OpenMobility Manager startup. The “Default” button sets all time zones back
to the default values and deletes the changed time zone rules in the
configuration file.
With the “Configure Time Zone” dialog the standard time and the daylight
savings time (DST) of a time zone can be changed. If the time zone has no
DST only the UTC difference can be configured. For the DST both points of
time (begin of standard time and begin of daylight savings time) have to be
specified exactly. Therefore a certain day in the month or a certain week day
in a month can be used. See the following screen shots as an example: