4.4.6 DECT monitor of the OpenMobility system
For a better error detection in the OpenMobility system the DECT monitor
can be used. The DECT monitor is an MS Windows based standalone
application. It provides the possibility to give a real time overview of the
current RFP and PP states in the DECT OpenMobility system.
The following features are provided by the DECT monitor:
Reading out of the DECT configuration of a OpenMobility system.
Configuration can be stored in an ASCII file.
Display of DECT transactions RFP-PP in clear tabular form, with
highlighting of handover situations. Real-time display.
Display of further events concerning the status or actions of RFPs
and PPs of the OpenMobility system.
All events can also be recorded in a log file.
Display of the synchronization relations between the RFPs.
Monitoring of systems with up to 255 RFPs and 1023 PPs.
Reading out and display of RFP statistics data, either for a single RFP or
for all RFPs.
Display of DECT central data of the OpenMobility system.
The DECT Monitor application can only be used if the DECT Monitor flag in
the OMM web service on the system settings configuration page is enabled.
The DECT monitor application is used together with the OpenMobility
system.
When the application is started, the user is requested to enter the IP address
of the RFP or server running the OpenMobility Manager (OMM) software.
This address is different from the IP address of the PABX the OMM is
connected to!
There can be several reasons for an unsuccessful link establishment:
Operation of DECT Monitor is not enabled inside the OMM. Use the web
service to enable the DECT Monitor operation.
IP address is not correct. It has to be the address of the RFP or server the
OMM is running on, not the address of the PABX!
A link routed through the PABX is not supported. In case of a remote
service on a PABX via dial-in the OMM can not be accessed from the
DECT Monitor.
The application displays the IP address which has been used last time.
When the application is started a link to the OpenMobility system is
automatically established and the application window shows all user
configured child windows and tables.
When all links have been established, the DECT data of the system is
automatically read out and entered in the tables “RFP-Table” and “PP-Table”.
This procedure is called “Config Request”.