Specifications
5
0003097 Revision A 7
3
Specifications
Environment
System
Storage Environment
Condition Specification
Temperature -40º to 150ºF (-40º to 66ºC)
Humidity 5-95% Relative Humidity, non-condensing
Vibration
(FCC Part 68, Sections 6&7)
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical Stress
(FCC Part 68, Sections 6&7)
One 20.3 cm (8 inch) drop, each edge and corner adjacent to the 
rest face
Horizontal Transportation Impact 
Stress
One shock pulse applied on each face perpendicular to the 
direction of motion of the transporting vehicle; the shock pulse is a 
half-sine acceleration 30 g peak, 20 ms duration
Operational Environment 
Condition Specification
Temperature 32º to122ºF (0º to 50ºC) Peripheral cabinet and DSU cabinet
32º to 104ºF (0º to 40ºC) SX-2000 MICRO LIGHT and 
Redundant Control cabinet 
Humidity 5-95% Relative Humidity, non-condensing
Maximum Heat Dissipation - fully 
loaded (see Note)
Redundant Control Cabinet 386 BTUs per hour
Non-redundant Control Cabinet 270 BTUs per hour
SX-2000 MICRO LIGHT Cabinet 1109 BTUs per hour
Peripheral Cabinet 724 BTUs per hour
DSU Cabinet 266 BTUs per hour
Air Flow 150 cubic feet per minute at maximum output of the fans
Radiated Emissions The system meets Class A limits as outlined in FCC Rules, Part 
15, Subpart J
Page 1 of 2