Specifications

S
X-2000 General Information Guide
4
Revision A 5000309
7
CEPT Links: The system supports MSDN/DPNSS, DASS II (UK only), and Italian CAS
(Italy only) protocols.
The SX-2000 LIGHT system connects to CEPT links by using a CEPT Formatter or CEPT
Formatter II card.
BRI Links: The BRI card supports Euro-ISDN 2B+D, Basic Rate, or North American
National ISDN-1 and ISDN-2 protocols.
The SX-2000 LIGHT system connects to BRI links by using a
BRI card. The BRI link can
be either User or
Network Termination (for European installations only).
PRI Links: The
PRI card and the ISDN Network Gateway support DMS-100, DMS-250,
Bellcore National ISDN, 4ESS, NI-2, 5ESS NI-2, Q.SIG and Euro-ISDN (CTR4) protocols.
The SX-2000 LIGHT system connects to PRI links by using a
PRI card or an ISDN Network
Gateway.
R2 Links: The R2 card supports the CCITT Blue Book, Volume VI, Fascicle VI.4, Speci-
fications of Signaling System R2, Recommendations Q.440 to Q.490 (with the exception
of Echo Suppression (Q.479), Test Calls (Q.490) and international signals).
The SX-2000 LIGHT system and SX-2000 MICRO LIGHT system connect to the R2 links
using an
R2 card.
The following analog trunks are supported:
Analog CO Trunks interface to the system through the
Loop Start/Ground Start (LS/GS)
trunk card
.
E&M Trunks interface to the system through the
E&M trunk card (which can be configured
for either 2-wire or 4-wire operation). This card supports Type I through Type V circuits.
Direct Inward Dial and Tie Trunks interface to the system through the DID/Loop Tie trunk
card, AC15 trunk card, DID/2 trunk card, or DID/3 trunk card (depending on local
requirements).