Specifications

S
X-2000 General Information Guide
7
6 Revision A 5000309
7
Power
Cabinet Type Power Source
Maximum AC Power
Input Watts
NA UK
Redundant Control 120 Vac 230.120 Vac 113 W
Non-redundant Control 120 Vac 230.120 Vac 79 W
SX-2000 MICRO LIGHT 120 Vac 230.120 Vac 325 W
Peripheral 120 Vac 230.120 Vac 212 W
DSU 120 Vac 230.120 Vac 78 W
Note: The type of Control Cabinet (Redundant or Non-redundant) and the number of Peripheral or
DSU Cabinets must be known before the Maximum Power and Heat Dissipation can be
determined.
Equipment Power Requirements
AC Control Cabinet, DSU Cabinet, and
Peripheral Cabinet
For more information, see the AC Power
Converter section of the Technical
Documentation CD-ROM.
120 Vac, 6 amps
240 Vac
The input power is converted to ±5, ±12, -27 and -48 Vdc, and 80 Vac
ringing voltage by the power converter (AC)
DC Control Cabinet, DSU Cabinet, and
Peripheral Cabinet
For more information, see the DC Power
Converter section of the Technical
Documentation CD-ROM.
-48 Vdc
In a DC powered peripheral or SX-2000 MICRO LIGHT node, the -48
V power is used directly. In a control or DSU node, the input power (AC
or DC) is converted to ±5 and ±12 Vdc and output by the PSU.
SUPERCONSOLE 1000 The console is powered from the line feed (-48 V). It has an on-board
power supply that converts the input voltage to +5, +15 and -8.0 Volts.
The on-board power supply draws 27 mA from input supply, + 10% at
-48 Volts. The Input voltage range is from 35 to 60 Vdc.
SUPERSET 7000 PC DNIC Card +5 Vdc ± 5%
-5 Vdc ± 10%
+12 Vdc ± 5%
-12 Vdc ± 10%
SUPERSET 700
SUPERCONSOLE 2000
120/240 Vac
Datasets Dataset receives power from a plug-in transformer which supplies 9
Vac to a power connector on the back of the dataset. Circuitry in the
dataset converts this power to the required DC voltages. The digital
telephone voice operation receives its power from the system.