7
Hardware Dimensions
Hardware Dimensions
Parameter Name
MFRD Level
14 16 18 20 21 22 23 24 26 40 42 44
Attendant Consoles, page 27, (Note 1) 8 16 24 24 24 24 48 48 24 2 4 6
DNI Channels (Note 2) 448 864 2368 1764 3988 3552 1504 1120 2368 64 96 192
DTRX Service (Data Transceiver
Circuits)
24 24 48 48 48 48 48 48 48 24 24 24
Modems 2 20 40 40 30 100 40 40 40 4 4 2
Programmable Key Modules (PKMs) 15 30 75 45 150 75 50 30 10 16 24 32
SUPERSET 700 Consoles (Note 3) 8 16 16 16 16 16 16 16 16 2 4 6
SUPERCONSOLE 2000 Consoles 8 16 16 16 16 16 16 16 16 2 4 6
System Ports (Note 4):
- Datasets 16 16 16 400 362 1000 200 200 400 16 16 16
- DTMF Receivers 64 128 128 160 128 128 128 128 128 64 64 64
- Multiline Sets 144 300 756 450 1600 756 504 300 756 32 48 96
- Single Line Sets (ONS/OPS Lines) 352 1360 2504 3500 456 1504 1504 1360 2504 32 48 96
- Trunks (Note 5) 144 312 628 628 400 628 1300 628 628 128 128 128
Tone Detector Circuits (Note 6) 32 32 32 32 32 32 32 32 32 32 32 32
Notes:
1.
The difference between the maximum number of SUPERSET 700 or SUPERCONSOLE 2000 consoles
allowed and the total number of attendant consoles allowed may be made up with SUPERCONSOLE 1000
units without the printer port enabled.
2. A DNI line card provides 16 DNI circuits with 2 DNI channels per circuit. Given the total number of DNI
channels, you can determine the maximum number of DNI line cards. For example, with MFRD 14, you can
have 448 DNI channels or 14 DNI line cards (448 divided by 2 x 16).
3. The maximum number of SUPERSET 700 or SUPERCONSOLE 2000 consoles that can be used in the system
depends on the Main Controller card and MITEL Traffic Capacity Level (MTCL). For the purposes of hardware
dimensions, a SUPERCONSOLE 1000 attendant console with its printer port enabled is treated as a
SUPERSET 700 or SUPERCONSOLE 2000 console.
4. Although the system dimensions permit support for these figures, each peripheral cabinet has a physical
maximum of 192 ports and each DSU cabinet has a physical maximum of 240 (multiplexed) ports.
5. When a trunk card is programmed in the System Configuration form, the maximum number of trunks is
allocated automatically. For example, 8 trunks will be allocated for the LS/GS card, and 4 trunks will be
allocated for the E&M card.
6. A Tone Detector card must be used to achieve the maximum 32 circuits. The 32 circuits on the Tone Detector
card replace the 10 tone detection resources on the Main Controller card.