Specifications
Capacity Levels, Software Configurations, and Dimension
s
5
0003097 Revision A 8
7
Hardware Dimensions (no longer sold)
Parameter Name
MFRD Level
1 2 3 7 12 25 27
Attendant Consoles (Note 1) 4 8 8 16 24 24 32
DNI Channels (Note 2) 256 448 704 864 2368 1764 1504
DTRX Service (Data Transceiver Circuits) 24 24 24 24 48 48 48
Modems 6 8 12 20 40 10 40
Programmable Key Modules (PKMs) 10 15 25 30 75 65 50
SUPERSET 700 Consoles (Note 3) 8 8 8 16 16 16 16
System Ports (Note 4):
- Datasets 48 64 96 112 400 100 208
- DTMF Receivers 64 128 128 128 128 160 128
- Multiline Sets 72 144 240 300 756 675 500
- Single Line Sets (ONS/OPS Lines) 192 352 752 1360 2504 2800 1000
- Trunks (Note 5) 112 144 204 312 628 628 1600
Tone Detector Circuits (Note 6) 32 32 32 32 32 32 32
Notes:
1. The difference between the maximum number of SUPERSET 700 consoles allowed 
and the total number of attendant consoles allowed may be made up with 
SUPERCONSOLE 1000 units without the printer port enabled.
2. A DNI line card provides 16 DNI circuits with 2 DNI channels per circuit. Given the total 
number of DNI channels, you can determine the maximum number of DNI line cards. 
For example, with MFRD 2, you can have 448 DNI channels or 14 DNI line cards (448 
divided by 2 x 16).
3. The maximum number of SUPERSET 700 consoles that can be used in the system 
depends on the Main Controller card and MITEL Traffic Capacity Level (MTCL). For 
the purposes of hardware dimensions, a SUPERCONSOLE 1000 attendant console 
with its printer port enabled is treated as a SUPERSET 700 console.
4. Although the system dimensions permit support for these figures, each peripheral 
cabinet has a physical maximum of 192 ports and each DSU cabinet has a physical 
maximum of 240 (multiplexed) ports.
5. When you program a trunk card in the System Configuration form, the maximum 
number of trunks is allocated automatically. For example, 8 trunks will be allocated for 
the LS/GS card and 4 trunks will be allocated for the E&M card. 
6. A Tone Detector card must be used to achieve the maximum 32 circuits. The 32 
circuits on the Tone Detector card replace the 10 tone detection resources on the 
Main Controller card.