9. Test the card
- Inspect the faceplate LEDs to verify that the card is
functioning.
Note: The replacement cards may take longer to boot-up than older card
versions.
- Open a maintenance window and verify that the trunks
associated with the corresponding channels are all in
idle state.
10.Upgrade or re-install the software:
Upgrades for the CEPT and DS1/T1 Formatter II cards
are done from the main controller each time its software
is upgraded. You can also use the force dl command
option in the VT 100 emulation window.
The CEPT and DS1/T1 Formatter I cards are not
upgradeable in the field as they come with the software
pre-loaded.
11.Reset the CEPT or DS1 Formatter I or II card using one
of the following methods:
- Entering the LOAD <PLID> command in the
maintenance window of the system.
- Unseat and reseat the card.
- Type the reset option command in the VT 100
emulation window.