Technical information
Routine Maintenance
173
Routine
Maintenance
17.If no update files were applied in step 14, proceed to the 
next step.
If updates were applied in step 14, hold down PANEL 
ENABLE and press A RESET. 
18.Go to Enable New Options on page 173 if
• new options are included with the software
• this is a new install
• you are loading software earlier than P02.3.2
Otherwise, go to Restore the Database on page 174.
Enable New Options
1. Log on to the system and select customer data entry 
mode.
2. Select System Forms from the Forms Group Menu.
3. Select Dimension and Feature Select form from the 
System Forms menu. Press the <edit form> softkey.
4. Set all options to match those on the SX-2000 Feature 
Options Record sheet that was shipped with the software 
(X = YES).
5. Select the machine configuration FD1 (for a 
MICRO-LIGHT or 9” non-redundant system) and set the 
maximum number of cabinets to 5 OR FD2 (for all other 
SX-2000 systems) and set the maximum number of 
cabinets to 12.
6. Press the <generate> softkey then the <bottom> softkey.
7. Enter the MITEL options password (from the SX-2000 
Feature Options Record sheet received with the 
software), press the <commit> softkey; then press the 
<confirm> softkey.
8. This message appears:
Changes committed. ** Reload the system to make new values 
effective. **
9. Quit the form.
10 min