Technical information
Routine Maintenance
177
Routine
Maintenance
DBMS Info: Save Completed
14. If your software is earlier than P02.3.2 AND you have the 
Property Management System (PMS) option, hold down 
PANEL ENABLE and press A RESET.
15.Enter:
TYPE ∗.DR.LOGFILE_1
Review the log for data that has not been restored. Do 
not proceed to the next step until lost data has been 
re-entered. Lost data may have to be re-entered 
manually.
16.Reload the software into all peripheral processors, DSU 
cards, DNI line cards, and attendant consoles. 
For software loads P17.6.4 and later, enter:
LOAD CONTROLLERS
For software loads earlier than P17.6.4,
– Turn power to SUPERSET 700 consoles off and then 
on again.
– Load DNI line cards. Enter:
LOAD <cabinet> <shelf> <slot> 
17.Enter:
DATE yyyy-mmm-dd hh:mm:ss
For example: DATE 1999-sep-28 14:43:45.
18.Reprogram your login usernames, passwords, and 
alarm thresholds.
19.Enter:
DBMS CH ON
to turn on automatic datasave checking.
20.If you have the Message Center option:
– Insert the RSD with your Message Center backup in 
the RSD drive
– Enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system 
response on the maintenance terminal.