Technical information
Technician’s Handbook
178
– Enter:
MSGC R ∗.<volume name of RSD>
– Enter:
VOL DISMOUNT <volume name of RSD>
21.Enter:
PROG R ON
To turn on the automatic system reload. By default, the 
system reboots at 2:15 AM daily IF there is memory 
fragmentation.
22.Perform the procedure Checking a Non-redundant 
System on page 157.
23.The software upgrade is complete.
Performing a Software Update on a Non-redundant 
System
1. Insert the software RSD into the RSD drive.
2. Enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system 
response on the maintenance terminal.
3. If an update already exists on the system enter:
UPDATE REMOVE
This message appears:
The Update has been removed. Please reload the main 
controller from the Winchester. Also reload the slaves that 
were changed (if any). 
The reload is optional. Continue to the next step to save 
time.
4. Enter UPDATE APPLY <volume name of RSD> FROM 
∗.<volume name of RSD>.
This message appears:
The update has been successfully applied. Please, reload the 
main controller from the Winchester. As well, reload the 
slaves that were changed (if any).
5. Enter VOL DISMOUNT <volume name of RSD>