Technical information

Technician’s Handbook
178
Enter:
MSGC R .<volume name of RSD>
Enter:
VOL DISMOUNT <volume name of RSD>
21.Enter:
PROG R ON
To turn on the automatic system reload. By default, the
system reboots at 2:15 AM daily IF there is memory
fragmentation.
22.Perform the procedure Checking a Non-redundant
System on page 157.
23.The software upgrade is complete.
Performing a Software Update on a Non-redundant
System
1. Insert the software RSD into the RSD drive.
2. Enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system
response on the maintenance terminal.
3. If an update already exists on the system enter:
UPDATE REMOVE
This message appears:
The Update has been removed. Please reload the main
controller from the Winchester. Also reload the slaves that
were changed (if any).
The reload is optional. Continue to the next step to save
time.
4. Enter UPDATE APPLY <volume name of RSD> FROM
.<volume name of RSD>.
This message appears:
The update has been successfully applied. Please, reload the
main controller from the Winchester. As well, reload the
slaves that were changed (if any).
5. Enter VOL DISMOUNT <volume name of RSD>