16.Enter:
UPDATE APPLY <volume name of RSD> FROM
.<volume name of RSD>
This message appears:
Update started
Update applied successfully.
OR
If there are no updates, this message appears:
ERROR: No update files were found
The update has not been applied
Ignore this error and go to the next step.
17.Enter:
VOL DISM <volume name of RSD>
18.Remove the software RSD from the RSD drive.
19.If no update files were applied in step 16, proceed to the
next step.
If updates were applied in step 16, hold down PANEL
ENABLE and press the inactive plane’s RESET button.
20.Go to Enable New Options on page 182 if
new options are included with the software
this is a new install
you are loading software earlier than P02.3.2.
Otherwise, go to Restore the Database to the Inactive
Plane on page 183.
Enable New Options
1. Log on to the inactive plane and select customer data
entry mode.
2. Select System Forms from the Forms Group Menu.
3. Select the Dimension and Feature Select form from the
System Forms menu. Press the <edit form> softkey.
10 min