Technical information
Routine Maintenance
187
Routine
Maintenance
attendant consoles. 
For software loads P17.6.4 and later, enter:
LOAD CONTROLLERS
For software loads earlier than P17.6.4
ā Turn power to SUPERSET 700 consoles off, then on 
again.
ā Load DNI line cards. Enter:
LOAD <cabinet> <shelf> <slot> 
20.Enter:
DATE yyyy-mmm-dd hh:mm:ss
For example: DATE 1999-sep-28 14:43:45
21.Proceed to Copy Upgraded Software to the Other Plane 
and JOIN the System on page 187.
Copy Upgraded Software to the Other Plane and JOIN 
the System
1. From the active plane, enter:
VOL SET SYSUSER READ ONLY
2. Insert the software RSD in the RSD drive.
3. Hold down PANEL ENABLE and press the inactive 
planeās RESET button.
4. Log on to the inactive plane and select maintenance 
mode.
5. If you are upgrading from software previous to Q26.13.1, 
proceed to step 7.; otherwise, proceed to step 6.
6. Enter:
FILE DIS RED
This message may appear:
FS error: File system redundancy could not be disabled. 
Reason: No such volume.
FS warning: Local disable can be attempted (Note: can lead to 
FS corruption).
FS info: Continue? (yes/no)
Enter YES
10 min