Technical information

Routine Maintenance
191
Routine
Maintenance
10.Hold down PANEL ENABLE and press the inactive
plane’s RESET button.
11.Log on to the inactive plane and select maintenance
mode.
12.To check the update version, enter:
VER
13.Hold down PANEL ENABLE and press ACTIVITY
SWITCH. Service is lost for 5 to 15 minutes.
14. Log on to the newly active plane and select maintenance
mode.
15.Reload the software into all peripheral processors, DSU
cards, DNI line cards, and attendant consoles.
For software loads P17.6.4 and later, enter:
LOAD CONTROLLERS
For software loads earlier than P17.6.4,
– Turn power to SUPERSET 700 consoles off then on
again.
– Load DNI line cards. Enter:
LOAD <cabinet> <shelf> <slot>
Copy the Software Updates from RSD to the Other Plane
1. Log on to the inactive plane and select maintenance
mode.
2. Insert the software RSD in the RSD drive.
3. From the inactive plane, enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system
response on the maintenance terminal.
4. Enter UPDATE APPLY <volume name of RSD> FROM
āˆ—.<volume name of RSD>
15 min